• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于LabVIEW的高压断路器操作机构状态评估
LabVIEW-based high-voltage circuit breaker operating mechanism of state assessment research
Received:July 10, 2015  Revised:November 19, 2015
DOI:
中文关键词: LabVIEW  开发  断路器操作机构  状态评估
英文关键词: LabVIEW, Develop, Circuit  breaker operating  mechanism, State  assessment
基金项目:国家电网科技项目(SGHLJG00YJJS1400303)
Author NameAffiliationE-mail
ZHAO Li-hua School of Electrical Engineering and Information Sichuan University,Sichuan Chengdu tyorika@163.com 
RONG Qiang* School of Electrical Engineering and Information Sichuan University,Sichuan Chengdu 1017728254@qq.com 
JING Wei State Grid Heilongjiang Power Company Limited maintenance company,Heilongjiang Harbin  
YANG Wei State Grid Heilongjiang Power Company Limited maintenance company,Heilongjiang Harbin 123456@qq.com 
JIANG Hai-yang State Grid Heilongjiang Power Company Limited maintenance company,Heilongjiang Harbin  
ZHANG Hao School of Electrical Engineering and Information Sichuan University,Sichuan Chengdu  
FU Rong-rong School of Electrical Engineering and Information Sichuan University,Sichuan Chengdu  
Hits: 2620
Download times: 785
中文摘要:
      本文基于LabVIEW软件平台开发了高压断路器操作机构状态评估系统,通过对机构分/合闸线圈电流波形曲线的纵向和横向比对综合评估操作机构的状态。实例分析表明该系统可评估机构电磁系统及机构本体和辅助开关的状态,及早发现操作机构的缺陷和故障隐患以便及时处理,从而提高高压断路器运行可靠性。
英文摘要:
      Based on LabVIEW software platform to develop a high-voltage circuit breaker operating mechanism status evaluation system, through institutions opening/closing coil current waveform curve of vertical and horizontal comparison of comprehensive to assessment the status of the operating mechanism. Example analysis shows that the system can evaluate the institutions electromagnetic system and mechanism body and the auxiliary switch status, early detection of defects and faults hidden operating mechanism for timely processing, thereby improving the operational reliability of the high voltage circuit breaker.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd