文章摘要
考虑电网多节点暂降的故障线路严重度评估
Severity evaluation of fault lines considering voltage sags at multiple buses in power system
Received:August 02, 2015  Revised:August 03, 2015
DOI:
中文关键词: 电压暂降  故障点法  熵权法  严重度系数
英文关键词: voltage sag, fault positions method, entropy method, severity coefficient
基金项目:
Author NameAffiliationE-mail
Lin Fang* School of Electrical Engineering Information,Sichuan University 423830583@qq.com 
Xiao Xianyong School of Electrical Engineering Information,Sichuan University  
Tang Lin School of Electrical Engineering Information,Sichuan University  
Hits: 2126
Download times: 788
中文摘要:
      针对现有暂降域分析方法的不足,提出一种新的故障线路严重度评估方法。基于故障点法,定义平均电压幅值、遭受不同深度暂降的节点数等指标,用以描述故障点的严重度。通过熵权法确定各指标权重,计算各故障点综合严重度系数。将位于同一线路的故障点综合严重度系数取均值,作为该线路的综合严重度系数,进而得到考虑多个敏感负荷节点暂降的故障线路严重度排序。仿真算例表明,所提方法能定量评估故障点和线路对关心节点造成的暂降严重度,为进一步采取暂降减缓措施提供参考依据。
英文摘要:
      A new method for evaluating the severity of fault lines is presented to overcome the shortcomings of existing methods for exposed area analysis. Based on fault positions method, average voltage magnitude index and the numbers of buses which suffer voltage sag with different magnitudes are used to describe the severity of fault positions. The weights of indexs are determined by using entropy method and the comprehensive severity coefficients of fault positions are then calculated. Average the comprehensive severity coefficient of fault positions which are in a same line to get the comprehensive severity coefficient of each line, and after that the fault line can be sorted considering the effect of voltage sag at multiple buses. Simulation example shows that the proposed method can quantitatively evaluate the severity of fault positions and lines , and can provide some references for adopting sag mitigation measure.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd