• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
一种用于VSC-HVDC谐波抑制的重复控制策略
A Kind of Repetitive Control Strategy for Harmonics Suppression of VSC-HVDC System
Received:August 14, 2015  Revised:August 15, 2015
DOI:
中文关键词: VSC-HVDC  改进型重复控制  奇次谐波  控制周期  稳态误差
英文关键词: VSC-HVDC  modified repetitive control  odd harmonics  control period  steady state error
基金项目:国家自然科学基金项目(51037003)
Author NameAffiliationE-mail
ZHAO Li-gang Electric Power Research Institute,Guang Zhou zhaolg@csg.cn 
ZHAO Yong Electric Power Research Institute,Guang Zhou zhaoyong@csg.cn 
Li Xing-yuan School of Electrical Engineering and Information,Sichuan University  
GUO Lei* School of Electrical Engineering and Information,Sichuan University gleisky@163.com 
ZHANG Ying-min School of Electrical Engineering and Information,Sichuan University  
Hits: 1698
Download times: 425
中文摘要:
      针对VSC-HVDC交流系统中5、7、11、13次谐波含量较大,采用一种改进型重复控制与PI调节器串联的控制方法。该方法的控制周期仅为传统重复控制周期的一半,具有较小的稳态误差,可以大幅度地消除系统各次奇次谐波。在PSCAD/EMTDC中搭建一个两端的VSC-HVDC系统,对未加重复控制、添加传统重复控制和改进型重复控制三种情况下换流站1、2侧交流电流的谐波含量进行仿真分析,结果表明改进型重复控制具有更好的谐波抑制效果。
英文摘要:
      In allusion to the high content of 5-, 7-, 11- and 13-order harmonics in the AC system of VSC-HVDC. A kind of control method is adopted by using series connection of modified repetitive controller and PI regulator, which has only half of the control period in traditional repetitive controller. Besides, it has smaller steady state errors and can achieve the function of eliminating the odd harmonics largely. A VSC-HVDC system of two terminals was built in PSCAD/EMTDC, through the simulation and analyses to the harmonic contents of the AC current in the side of converter 1 and 2 without repetitive control added, with traditional repetitive control added and the modified one respectively. The result validates that the modified repetitive control has a better function of suppressing the harmonics.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd