• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
地铁牵引供电系统中有源滤波器谐波控制研究
Control of Active Harmonic Filter in Metro Traction Power Supply System
Received:September 18, 2015  Revised:October 27, 2015
DOI:
中文关键词: 地铁  牵引供电  有源滤波  谐波控制
英文关键词: Metro  Traction Power Supply  active filter  harmonic control
基金项目:自然科学基金项目51147011;中央高校基本科研业务费专项资金项目2010QNB34
Author NameAffiliationE-mail
huangkai* China university of mining and technology 250598107@qq.com 
zhangdongliang China university of mining and technology 1402270245@qq.com 
liujuan China university of mining and technology 1402270245@qq.com 
xieyehua China university of mining and technology 1402270245@qq.com 
Hits: 1649
Download times: 567
中文摘要:
      地铁牵引供电系统中多采用的是24脉波整流机组,是由两组12脉波整流机组并联组成。如果两组12脉波整流机组工作不稳定会产生大量的谐波,对地铁安全运行产生威胁。因此从整流机组的整流特性进行谐波分析,针对24脉波整流机组加入三电平有源滤波器进行谐波控制。本文主要对三电平有源滤波器的拓扑结构及控制算法进行深入分析和研究。最后通过仿真与实验结合说明该有源滤波器对地铁24脉波整流牵引供电系统非特征次谐波控制有一定的补偿作用。
英文摘要:
      Metro Traction Power Supply System in the use of the 24-pulse rectifier unit , is composed of two 12-pulse rectifier unit connected in parallel. If two 12-pulse rectifier unit will generate a lot of job insecurity harmonics, a threat to the safe operation of the subway. Therefore, from the harmonic analysis of the rectifier unit rectifying characteristics, harmonic control for 24-pulse rectifier unit added three-level active filter. This paper focuses on topology and control algorithm of the three-level active filter to analysis and research. Finally, the combination of simulation and experiment shows that the active filter on the subway 24-pulse rectifier traction power supply system non-characteristic harmonic control has some compensation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd