1030MW发电机转子一点接地保护误报警的分析及处理
Analysis and management on rotor one-point grounding protection malfunction of 1030MW generator
Received:December 05, 2015  Revised:December 05, 2015
DOI:
中文关键词: 转子一点接地保护  误报警  大轴接地  数学模型
英文关键词: rotor one-point grounding protection, malfunction, the shaft grounding, mathematic model
基金项目:
Author NameAffiliationE-mail
Yu Kai* CPI Henan Company Technology and Information Center syyukai@163.com 
Xue Song State Grid Henan Pingdingshan Power Supply Company 1191951697@qq.com 
Yuan Feifan State Grid Henan Pingdingshan Power Supply Company 9809588@qq.com 
Wang Peng CPI Henan Company Technology and Information Center pdsyui@163.com 
Hits: 1959
Download times: 1019
中文摘要:
      转子一点接地是汽轮发电机常见的故障形式之一。本文结合某1030MW发电机转子接地保护运行中“转子一点接地”误报警问题,现场检查排除了发电机转子外部接地情况,通过试验确定汽端大轴接地铜辫处的打火放电是造成误报警的原因。结合该保护装置建立数学模型,对所采用的不同保护方式分别进行理论分析,找到理论上可能导致报警误发的原因,总结出发电机转子接地报警后的排查重点,以指导同类型发电机运行检修工作。
英文摘要:
      Rotor one-point grounding is one of familiar faults of the turbine generator. This article elaborated and analyzed an incident that A rotor grounding protection device of 1030MW generator alarmed when the generator was running. After check, no grounding points were found in the exterior of the generator, and it was sure that sparks existing in the copper grounding braids of the shaft in the turbine end were the reason for this alarm by a test. This article built mathematic models according to protection devices, elaborated the reason for malfunction of different protection devices, and indicated what should be lay emphasis on in the check when alarm appeared. It will be beneficial to the operation and maintenance of the same-type generator.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd