微网线路保护综述
Overview on Micro-grid line Protection
Received:January 07, 2016  Revised:April 02, 2016
DOI:
中文关键词: 微网  线路保护  逆变器  分布式电源
英文关键词: microgrid  line protection  inverter  distributed generator
基金项目:国家自然科学基金项目(面上项目,重点项目,重大项目)
Author NameAffiliationE-mail
XIA Ling-qin* College of Electrical Engineering,Xinjiang University 1225244143@qq.com 
LI Feng-ting College of Electrical Engineering,Xinjiang University xjlft2009@sina.com 
Hits: 1446
Download times: 501
中文摘要:
      含逆变器微源的微网线路故障时,由于逆变器的限流作用,流过逆变器的故障电流被限制在两倍额定电流以内,造成含逆变器微源的微网并、离网模式下故障电流差距较大,使得基于固定值的常规过流保护不适用于微网。基于上述问题,对造成微网线路故障电流不确定性的影响因素作了总结,主要有微网运行方式,DG接入退出、布局容量、控制方式,并对它们的影响作了分析。着重综合概括了目前国内外微网线路保护研究热点,并按是否依赖通信及保护原理的实现方法做了划分。最后针对目前微网线路保护存在的问题探讨了其可能的发展方向。
英文摘要:
      The fault current of the inverter is limited to two times of the rated current, which causes the huge difference of the fault current in grid-connected and islanded mode of micro-grid containing inverter type micro source. The conventional overcurrent protection based on the fixed value is not suitable for the micro network any more. There are many factors that cause the uncertainty of fault current, which are summarized, such as, the operation mode of micro-grid,the exit,the capacity ,the layout and the control mode of DG, and analyzed their impacts. Current domestic and international research hotspot of microgrid line protection are summarized, and also maked classifications on whether rely on communications and realization method of protection principle. Finally, it is discussed the possible future development direction of the microgrid line protection.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd