• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于DSP和改进ip-iq算法的不对称系统补偿指令电流检测
Compensation command current detection based on DSP and improved ip-iq algorithm in asymmetric systems
Received:January 19, 2016  Revised:January 19, 2016
DOI:
中文关键词: 不对称系统  改进ip-iq算法  基波正序电流失量坐标  DSP
英文关键词: asymmetric system, improved ip-iq algorithm, coordinate of fundamental positive current vector, DSP
基金项目:
Author NameAffiliationE-mail
Gong Maofa College of Electrical Engineering and Automation,Shandong University of Science and Technology sdgmf@163.com 
Zhang Xutong* College of Electrical Engineering and Automation,Shandong University of Science and Technology zhangxutong2@126.com 
Gong Zheng State Grid Weifang Power Supply Company zhangxutong2@126.com 
Jiang Wen State Grid Weifang Power Supply Company zhangxutong2@126.com 
Hits: 2083
Download times: 1072
中文摘要:
      为了解决传统ip-iq方法在三相电网电压不对称时不能准确提取基波正序有功和无功电流的问题,增加三相电压同步参与abc/α-β坐标变换,给出在α-β坐标系中求取瞬时基波正序有功(无功)电流矢量坐标的数值计算方法,并设计了以TMS320F2812为核心的采样系统。通过MATLAB/SIMULINK环境仿真,搭建三相电网不平衡系统,并与传统ip-iq检测有功电流进行测试比较,证明了该方法获取基波正序补偿指令的精确性。
英文摘要:
      In order to solve the problem that traditional ip-iq method can not accurately extract fundamental positive active and reactive current in three-phase asymmetric grid, three-phase voltage is added to the abc/α-β coordinate conversion synchronously, and numerical method is proposed to seek coordinates of instantaneous fundamental positive active (reactive) current vector in α-β coordinate system, and design TMS320F2812 as the core sampling system. It is proved that the way to get fundamental positive compensation command is accurate comparing with traditional ip-iq detection under the conditions of three-phase asymmetric grid in MATLAB / SIMULINK simulation environment.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd