• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于时间-电流曲线的变压器剩磁检测方法研究
Study on transformer Residual Flux detection method based on the time-current curve
Received:February 23, 2016  Revised:February 23, 2016
DOI:
中文关键词: 磁滞现象  时间-电流  剩磁检测  恒压源  
英文关键词: hysteresis  time-current  residual flux detection  voltage source
基金项目:
Author NameAffiliationE-mail
Niu Shuaijie* School of Electrical Engineering and Information,Sichuan University 285370383@qq.com 
Zhao Lihua School of Electrical Engineering and Information,Sichuan University tyorika@163.com 
Chen Ling Sichuan Electric Power Science Research Institute cxxxz@163.com 
Feng Zhengsong School of Electrical Engineering and Information,Sichuan University 465739651@qq.com 
Niu Chunchun School of Electrical Engineering and Information,Sichuan University 876336059@qq.com 
Hits: 1995
Download times: 382
中文摘要:
      本文从铁磁材料固有的磁滞现象角度分析了变压器剩磁产生的原因,提出了基于时间-电流曲线的变压器剩磁检测的方法。通过对电力变压器原边加载幅值相同的正负恒压源对变压器进行充放电,得到变压器的“时间-电流”曲线以判定变压器中有无剩磁及剩磁的极性。仿真及实验结果表明,基于时间-电流曲线的剩磁检测方法能够准确测量变压器是否存在剩磁及剩磁的极性,为变压器合理投切及抑制励磁涌流提供了参考依据。
英文摘要:
      This paper analyzes the reason of transformer residual flux resulting from the inherent hysteresis in the ferromagnetic material, and presents a novel method to detect transformer residual flux based on the time-current curve. Through theSpower transformer primarySloadSthe same amplitudeSpositive and negativeSSvoltage sourceSto charge and discharge,Sestablishing a “time-current” curveSto determineSwhether theStransformerShasSresidual flux andSpolarity of residual flux.SMATLAB simulation andSexperiment test and verify transformer residual flux detection method based on the time-current curve can accurately measure whether the transformer
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd