文章摘要
基于采样值相关度的广域后备保护算法
A Wide Area Back-up Protection Algorithm Based on the Correlation ofSample Value
Received:March 11, 2016  Revised:April 08, 2016
DOI:
中文关键词: 广域后备保护,CT断线,采样值相关度,关联IED,数据同步
英文关键词: wide  area back-up  protection, CT  break, correlation  coefficient of  the sample  value, associated  IEDs, data  synchronization
基金项目:
Author NameAffiliationE-mail
Kong Dehong* School of Electrical Engineering and Information,Sichuan University 504296972@qq.com 
Lü Feipeng School of Electrical Engineering and Information,Sichuan University 664484949@qq.com 
Hits: 1714
Download times: 832
中文摘要:
      为解决传统后备保护整定配合复杂,发生CT断线时无法识别故障等问题,提出了一种基于采样值相关度的广域后备保护算法。该算法充分利用电网的电压、电流信息,以关联IED的采样值相关度构成保护判据。发生CT断线时,通过关联矩阵进行关联IED搜索,根据关联IED的相关度和虚拟CT的相关度大小关系区分线路故障和母线故障。该算法对采样同步精度要求低,发生CT断线时依然能正确识别并切除故障元件。最后基于 PSCAD 搭建IEEE 3机9节点系统进行仿真验证,结果表明:该算法能准确识别线路和母线上的各种类型故障,具有良好的动作性能。
英文摘要:
      In order to solve the problems of setting and coordination of the traditional back-up protection and its malfunction when CT breaks, a wide area back-up protection algorithm based on the correlation of sample value is proposed. The algorithm makes full use of the voltage and current information of the power grid, and the protection criterion is constituted based on the correlation of the sample value of the associated IEDs. Associated IEDs is searched through the associated matrix when CT breaks. The fault element is identified according to the correlation of the associated IEDs and the correlation of the virtual CT. This algorithm is still effective when synch precision is low and CT breaks. Finally, an IEEE 3-machine and 9-bus system is constructed by PSCAD, the results of the correlation degree of sample value show that the proposed algorithm can identify various types of faults on line and bus, and has good operational performance.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd