文章摘要
基于双平衡桥探测直流系统接地故障检测的新方法
A new Method to Detect DC Circuit Grounding Fault Based on the Double Balanced Bridge
Received:March 20, 2016  Revised:March 20, 2016
DOI:
中文关键词: 直流系统  接地故障  双平衡桥探测  绝缘监测
英文关键词: DC system  Grounding fault  Double balanced bridge  Fault detection
基金项目:
Author NameAffiliationE-mail
HUANG Jing Electronic and Information Engineering College,Shanghai University of Electric Power Shanghai 200090 tchs2190@163.com 
ZHU Wu* Electronic and Information Engineering College,Shanghai University of Electric Power Shanghai 200090 zjmzwzsy@126.com 
Hits: 1927
Download times: 502
中文摘要:
      针对电桥法、变频法等常用接地故障检测方法的不足,本文提出了一种新的双桥探测法用于直流系统的故障检测,该方法通过可编程控制器控制开关两次投切电阻,检测双桥不平衡电流以及支路漏电流,并计算接地故障电阻,从而定位接地支路。首先详细阐述了双桥探测的基本原理及应用,然后提出一种新的双桥探测法,该方法不仅能够解决检测死区问题,并且不受分布电容的影响。最后通过模拟接地电阻试验证实了该方法的可行性和有效性。
英文摘要:
      To solve the lack of common methods of ground fault detection method, this paper proposes a new double balance bridge detection method for DC system circuit grounding fault detection. In this method, the programmable controller switches twice resistance switching, and then monitoring unbalance current in the double balance bridge and the branch leakage current, calculating the ground fault resistance and positioning the grounding branch. This paper first expounds the basic principle and application of double bridge detection, and then proposes a new double balance bridge detection method to solve the problem of detection of dead zone and this detection method is not affected by the influence of distributed capacitance. Finally, through experiments proved the feasibility and effectiveness of this method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd