单相光伏逆变器直流母线电压二次波动对系统影响的分析与抑制
Analysis and Suppression of Effect of Secondary Voltage Disturbances of DC bus for Single-phase PV Inverter
Received:March 21, 2016  Revised:March 21, 2016
DOI:
中文关键词: 直流母线电压二次波动  单相光伏逆变器  双闭环控制策略  周期积分器  谐波分析
英文关键词: secondary voltage disturbances of DC bus, single-phase photovoltaic inverter, double closed-loop control strategy, cycle integrator, harmonic analysis
基金项目:
Author NameAffiliationE-mail
Chen Ruicheng* College of information and electrical engineering,China University of Mining and Technology crch1992@163.com 
Miao Jiazhen College of information and electrical engineering,China University of Mining and Technology 783253155@qq.com 
Hu Cong College of information and electrical engineering,China University of Mining and Technology 1184999018@qq.com 
Geng Yiwen College of information and electrical engineering,China University of Mining and Technology 13913475362@139.com 
Hits: 1956
Download times: 479
中文摘要:
      基于传统双闭环控制策略的单相光伏并网逆变器会造成直流母线电压的二次波动,导致并网电流中含有三次谐波,影响输出电能质量。针对上述问题,在分析直流母线电压二次波动产生机理的基础上,本文提出一种在直流母线电压采样前加入周期积分器的双闭环控制策略。该控制策略能够消除因直流侧二次波动导致的并网电流三次谐波,有效抑制直流母线电压二次波动对系统输出电能质量造成的影响。仿真和实验验证了该方法的合理性与有效性。
英文摘要:
      In single-phase photovoltaic grid-connected inverter based on the double closed-loop control strategy, the secondary voltage disturbances of DC bus will be generated, resulting in the triple harmonic of grid current ,and affecting electrical energy quality. In view of these problems, based on analyzing the causes of the secondary voltage disturbances of DC bus,an double closed-loop control strategy increasing cycle integrator before DC bus voltage sampling is proposed in the article. The strategy can remove the triple harmonic of grid current cased by the secondary voltage disturbances of DC bus,and then effectively suppress the effect on electrical energy quality. Simulation and experimental results are given to verify the rationality and effectiveness of the strategy.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd