• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
单相变压器漏感参数识别计算方法研究
Research of leakage inductance identification method of transformers
Received:May 18, 2016  Revised:June 25, 2016
DOI:
中文关键词: 变压器  漏感测量  最小二乘法  参数识别
英文关键词: Transformer, measurement of leakage inductance, least square method,parameter identification
基金项目:国家自然科学基金资助项目(51377175)
Author NameAffiliationE-mail
Zhou Zehong Chongqing Electric Power Construction Company,Chongqing 896889101@qq.com 
Yao Chenguo* Chongqing University Yaochenguo@cqu.edu.cn 
Wang Junkai Chongqing University 543566276@qq.com 
Liu Xin Chongqing University 840143139@qq.com 
Hits: 1796
Download times: 707
中文摘要:
      变压器漏感参数的识别可以作为变压器故障判别依据,对变压器漏感的准确识别是变压器故障判别的关键。根据回路平衡方程,提出了基于最小二乘法的单相变压器的漏感识别方法。并通过EMTP-ATP仿真和动模实验室的单相变压器试验验证,仿真测得漏感识别相对误差<0.2%,试验测得变压器的漏感与铭牌参数计算的漏感值相对误差3.84%。此外,还在变压器不同饱和程度和不同频率下测量了变压器的漏感值。试验结果表明,基于二乘法的变压器漏感参数识别方法能够正确识别变压器的漏感值,变压器的漏感值与其饱和程度和频率无关。
英文摘要:
      The leakage inductance identification of power transformer can be regarded as the basis of fault identification. The accuracy of leakage inductance identification is the key of transformer fault identification. Therefore, according to equivalent circuit equations, leakage identification methods of single-phase transformer and three-phase transformer based on least square method were proposed in this paper. The relative error of leakage inductance measurement using EMTP-ATP simulation is below 0.2%. Transformer experiments were conducted on a single-phase transformer, which is used in dynamic simulation laboratory. The relative error of the test results compared with the calculating results on the light of nameplate is 3.84%. In addition, leakage inductance were measured under different frequency and different saturation level. Results show that the leakage inductance of transformer can be accurately measured by leakage inductance identification method based on least square method, and the leakage inductance is not sensitive to frequency and saturation level.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd