一种基于全景状态监测数据的新型架空输电线路状态评估模型
A new state evaluation model for transmission lines based on panoramic condition monitoring data
Received:July 06, 2016  Revised:July 06, 2016
DOI:
中文关键词: 输电线路  监测数据  状态评估  模型
英文关键词: transmission line  monitoring data  state evaluation  model
基金项目:
Author NameAffiliationE-mail
WANG Haitao* Wuhan NARI Limited Liability Company of State Grid Electric Power Research Institute 694907921@qq.com 
LIU Chunxiang Wuhan NARI Limited Liability Company of State Grid Electric Power Research Institute alexliu007@qq.com 
GUO Jiang Wuhan Relabo Energy Technology Co. Ltd guo.river@163.com 
Hits: 1472
Download times: 1026
中文摘要:
      本文结合目前输电线路监测现状,选取普洱供电局典型输电线路为载体,综合各种先进监测手段和技术方法,构建基于“点、线、面”全景监测数据的输电线路状态监控体系,结合监测数据及其它线路运行参数,建立输电线路动态化状态评估模型,通过现场实际运行验证,有效筛选出重点巡查的线路或重要部件,提升了线路运维水平。
英文摘要:
      Based on the transmission line monitoring of the status,this paper selects the typical transmission lines of Puer power supply bureau as the carrier, and synthesizes various advanced monitoring methods and techniques, and builds the transmission line state monitoring system based on the "point, line and surface" panoramic monitoring data. Based on the monitoring data and the operation parameters of other lines, the dynamic state evaluation model of transmission line is established. Through the actual operation of the site verification, it can effectively filter out line or an important component focused inspections, enhancing the operation and maintenance of the line level.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd