数字化变电站合并单元插值误差对于电能计量的影响
The influence of digital substaition merging unit interpolation error on electric energy measurement
Received:July 25, 2016  Revised:July 26, 2016
DOI:
中文关键词: 数字化变电站,电能计量装置,合并单元,电能计量误差
英文关键词: digital  substation, electric  energy metering  device, merging  unit,electric  energy metering  error
基金项目:
Author NameAffiliationE-mail
SongXiaolin State Grid Shaanxi Electric Power Company Electric Power Science Research Institute sxlgoodluck@163.com 
RenWei State Grid Shaanxi Electric Power Company Electric Power Science Research Institute,Xi’an 185381655@qq.com 
ZhangZhenduo Xi’an JiaoTong University 352955103@qq.com 
YangXing Xi’an JiaoTong University 905108277@qq.com 
ZengXiangjun* Department of Electrical Engineering, Xi’an JiaoTong University zengxj@mail.xjtu.edu.cn 
Hits: 2392
Download times: 625
中文摘要:
      作为电子式互感器与二次设备之间的纽带,合并单元负责为变电站全站提供统一的电压电流数据来源。然而,采样值数据在采样、处理和传输的各个环节中产生的粗大数据、通讯延时和丢包等问题都会对合并单元的插值处理带来影响,并最终影响到对电能的计量。本文就以上典型问题对合并单元插值算法及其对电能计量误差的影响进行了仿真分析,并搭建了数字化变电站电能计量装置误差测试系统对仿真结果进行了实验验证。结果表明,这些典型问题对合并单元的插值算法以及电能计量误差是有重大影响的,且采用不同的插值算法其影响结果不同。本文的研究为数字化变电站合并单元插值算法的优化设计提供了定量参考。
英文摘要:
      As a link between the electronic transducer and the two device, the merging unit is responsible for providing a unified voltage and current data source for the substation.However, the sampling value in data sampling, processing and transmission links generated in large data, communication delay and packet loss and other issues will be on the merging unit interpolation processing effects, and ultimately affect the measurement of electric energy.Based on the above typical issues of merging unit of interpolation algorithm and the impact of electrical power measurement error is analyzed, and build the digital substation system can test the metering error of the simulation results were verified by experiments.The results show that the typical problems of interpolation on the merging unit and the measurement error of electric energy is a significant impact, and the use of different interpolation algorithms the results of different effects.This study provides a quantitative reference for the design and optimization of interpolation algorithm for merging unit in digital substation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd