• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
一种台区漏电保护断路器的远程监控方案
The remote monitoring and control scheme for transformer area earth leakage circuit breaker
Received:July 27, 2016  Revised:September 14, 2016
DOI:
中文关键词: 用电信息采集系统  单相智能电能表  集中器  智能电网  漏电保护断路器  远程监控
英文关键词: Electric  Energy Data  Acquirement System, Single-Phase  Intelligent Electric  Meter, Concentrator, Intelligent  Electric Grid, Earth  Leakage Circuit  Breaker, Remote  Monitoring and  Control
基金项目:
Author NameAffiliationE-mail
wangshaohuai* STATE GRADE 13807334840@139.com 
lijianming STATE GRADE youngbeny@163.com 
Hits: 2058
Download times: 767
中文摘要:
      因非永久性故障引起的台区漏电保护断路器跳闸是配网运维中的常见故障,实现可靠的漏电保护断路器运行状态实时监测及控制是提高运维效率的可行思路。本文提出了一种基于电力用户用电信息采集系统的台区漏电保护断路器的远程监测控制方案,通过引入“集中器-单相智能电表-漏电保护断路器”的组合运行方式,利用采集系统传送状态及控制信息以实现漏电保护断路器的远程监控。现网试验运行结果表明,该方案能实现准确的漏电保护断路器状态变位的实时监测及非永久性故障的远程合闸,具有投资少、易实现、效果明显的优点。
英文摘要:
      Trips of earth leakage circuit breakers in transformer areas caused by non-permanent failure are common faults in the maintenance of distribution network, realization of real-time monitoring and control for earth leakage circuit breakers is feasible ideas to improve the efficiency of operation and maintenance. In this paper, based on the Power User Electric Energy Data Acquirement System, a remote monitoring and control scheme for earth leakage circuit breakers in transformer areas is issued. By introducing a "concentrators - single-phase intelligent electric meters - earth leakage circuit breakers is used status and control information of earth leakage circuit breakers is transferred in Electric Energy Data Acquirement System in order to achieve remote monitoring and control. The results of test in the real electric network show that the scheme can monitor the accurate status change of earth leakage circuit breakers, and do the remote reclosing of non-permanent failure in a higher success ratio. It has the advantages of less investment, easier implement and more obvious effects.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd