基于有限元法的±500kV同塔双回线路电磁环境仿真计算
Simulation Calculation of Electromagnetic Environment of ±500kV Double-circuit Transmission Line Based on Finite Element Method
Received:August 03, 2016  Revised:August 03, 2016
DOI:
中文关键词: 同塔双回  带电作业  COMSOL  仿真计算
英文关键词: double-circuit  live working  COMSOL  simulation calculation
基金项目:中国南方电网公司重点科技项目(K-GY2014-17)
Author NameAffiliationE-mail
ZENG Yanjun* School of Electrical Engineering,Wuhan University,Hubei Wuhan 564560198@qq.com 
WANG Tong School of Electrical Engineering,Wuhan University,Hubei Wuhan zyjforwangtong@163.com 
LI Yi School of Electrical Engineering,Wuhan University,Hubei Wuhan zyjforliyi@163.com 
SHENG Huaxia School of Electrical Engineering,Wuhan University,Hubei Wuhan yanjunzeng1991@sina.com 
Hits: 1796
Download times: 688
中文摘要:
      为了研究±500kV同塔双回直流输电线路的电磁场环境对带电作业人员的影响,以及对该输电线路带电作业安全防护提供理论仿真研究。本文以±500kV同塔双回直流输电线路型号为Z101的直线塔作为研究对象,采用SoildWorks和COMSOL混合建模技术,建立了直线塔的三维模型。针对6种典型的带电作业位置,本文采用COMSOL软件对Z101直线塔的电场和电势分布进行了仿真研究。研究结果表明:5号作业位置的人体电势差最大,且除了4号和5号作业位置外,其他作业位置人体电势差值接近;此外,作业人员器官的最大电场强度出现在颈部和四肢处;5号作业位置处人体各器官的电场强度是最大的,普遍超过了规定安全作业限值。因此作业人员在该同塔双回直流输电线路上进行带电作业时,应穿戴屏蔽服,并做好其他安全防护措施;且本文研究结果可为其他工程提供技术参考。
英文摘要:
      In order to study the influence of electromagnetic environment of ±500kV double-circuit transmission line on live working, and provide the theoretical and numerical simulation studies of safety protection of live working.This paper takes the Z101 line tower of ±500kV double-circuit transmission line as the research object, and establishs a three-dimensional model of the line tower with the mixed modeling techniques based on COMSOL and SoildWorks. Using COMSOL, study of simulation is carried out towards the electric field and potential distribution of Z101 line tower according to the six different topical live working positions. The results show that: the potential difference of NO.5 position is the maximum. The potential differences of all the other positions except No.4 and No.5 are similar; besides, the maximum electric field strength of human organs apears on the neck and limbs; and the electric field strength of human organs of No.5 position is the strongest, which generally exceeds the limit value of safety operation. Therefore, the worker should wear screen clothes and make other safety precaution efforts before live working in the double-circuit DC transmission line, and the results of this paper could provide the technical reference of other projects.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd