• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
一种用于柔性直流输电系统的能效计量方案
An energy efficiency measurement scheme for flexible HVDC system
Received:August 03, 2016  Revised:September 20, 2016
DOI:
中文关键词: 柔性直流输电  能效计量  损耗  模块化多电平换流器
英文关键词: flexible  HVDC, energy  efficiency measurement, loss, modual  multilevel converter
基金项目:国家电网公司科技项目(5211DS150010)
Author NameAffiliationE-mail
Zhang Jiangming* Electric Power Research Institute of State Grid Zhejiang Electric Power Company zjming@zju.edu.cn 
Hu Yingjun Electric Power Research Institute of State Grid Zhejiang Electric Power Company hzieer@qq.com 
Yao Li Electric Power Research Institute of State Grid Zhejiang Electric Power Company 13606619992@139.com 
Han Xiaohan Electric Power Research Institute of State Grid Zhejiang Electric Power Company zjming@zju.edu.cn 
Shen Shuming Electric Power Research Institute of State Grid Zhejiang Electric Power Company zjming@zju.edu.cn 
Yang Yaojia School of Electrical Engineering, Wuhan University 1434637086@qq.com 
Hits: 2265
Download times: 819
中文摘要:
      为评估柔性直流输电系统各能耗设备及整体系统的损耗,本文提出一种用于柔性直流输电系统的能效计量方案,该方案通过对柔性直流输电系统各个设备损耗的理论计算,结合能耗率、经济性、谐波影响等因素,确定了相关能效计量点的选择。同时,根据误差传递理论分析了计量装置的准确度等级要求。本方案对柔性直流输电系统的能效计量分析可起到借鉴作用。
英文摘要:
      To assess the loss of flexible HVDC system of each device and overall system. An energy efficiency measurement scheme for flexible HVDC system is proposed in this paper. In this scheme, the selection of revelant energy efficiency measurement point is determined by analysing the loss of each energy consumption equipment in flexible HVDC system combined with energy consumption rate, economy, harmonic influence and so on. Moreover, the accuracy of measuring device is analyzed according to the error transfer theory. This scheme provides reference for the energy efficiency analysis of flexible HVDC system.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd