±1100kV特高压直流输电工程辐射电磁干扰水平评估
Radio electromagnetic interference level evaluation of±1100kV UHVDC project
Received:August 08, 2016  Revised:August 08, 2016
DOI:
中文关键词: 特高压直流输电  换流阀厅  电流元  辐射电磁干扰  矩量法  
英文关键词: UHVDC  Converter valveShall  Current element  Radio electromagnetic interference  MOM  
基金项目:
Author NameAffiliationE-mail
Luo Hanwu State Grid East Inner Mongolia Electric Power Maintenance Company 1340895569@qq.com 
Le Jian* School of Electrical Engineering, Wuhan University lej01@mails.tsinghua.edu.cn 
Wang Yinge School of Electrical Engineering, Wuhan University 1464560699@qq.com 
Li Mengke State Grid East Inner Mongolia Electric Power Maintenance Company 1540641364@qq.com 
Xu Xinyao State Grid East Inner Mongolia Electric Power Maintenance Company 18672838112@qq.com 
Cui Shigang State Grid East Inner Mongolia Electric Power Maintenance Company 823796962@qq.com 
Hits: 2395
Download times: 830
中文摘要:
      进行特高压直流输电工程阀厅内电磁干扰水平评估对于研究其电磁干扰水平,制定针对性干扰抑制措施具有重要理论价值和现实意义。本文首先分析了±1100kV特高压输电工程换流阀的结构,分析了换流阀厅内主要辐射电磁干扰的来源。基于电流元模型构建辐射电磁干扰评估模型,采用矩量法进行求解。以实际工程为研究对象,基于PSCAD仿真得到电流元模型参数,利用FEKO软件进行了该工程换流阀厅辐射电磁干扰水平的评估。本文为特高压直流输电工程电磁干扰抑制措施的制定提供了依据。
英文摘要:
      It is of great theoretical value and practical significance to research radio electromagnetic interference(RI) in UHVDC Valve Hall, given the study on its level and the measures that is taken to reduce it. In this paper, . In this paper, the structure of ±1100 kV converter station valve hall and its main RI source is analyzed。And then, the RI model for its evaluation is built which is based on the current model, solved by the method of moments(MOM).Finally, taking the actual project as the research object, based on parameters of the current element model are obtained though the PSCAD simulation, the level of RI in ±1100 kV converter station valve hall is evaluated by using FEKO. This paper provides a basis for the measures for RI suppression of UHVDC.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd