• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
分布式电源对配电网电流保护的影响
Research on Current Protection of Distribution Network with DG
Received:October 18, 2016  Revised:November 09, 2016
DOI:
中文关键词: 分布式电源  PSCAD  自适应电流保护
英文关键词: distribution generation, PSCAD, adaptive current protection
基金项目:
Author NameAffiliationE-mail
Wang Xunzhe* School of Electrical Engineering, Wuhan University 1850157751@qq.com 
Hits: 1579
Download times: 653
中文摘要:
      本文在阐述分布式电源研究的背景和意义基础上,建立了分布式电源(DG)的恒功率等效模型,详细讨论了分布式电源在故障点不同位置时,其对配电网原有三段式电流保护产生的具体影响。在PSCAD仿真软件中,搭建了含DG的10kV配电网典型模型,利用全波傅立叶算法对短路电流进行计算,通过与所配置保护的整定值对比验证了理论分析的正确性。本文提出了基于本地信息量的自适应电流保护方案,为并入DG 后的配电网继电保护算法研究提供了一定的理论依据。
英文摘要:
      On the basis of pointing out the background and significance of distributed generation, this paper establishes a constant power equivalent model of distributed generation (DG). This paper analysis the specific effects to original current protection from a theoretical point of view when the distributed generation is at different location of the fault. In PSCAD simulation software, this paper builds a typical model of 10kV distribution network with DG and uses full-wave Fourier algorithm to calculate the magnitude of the short circuit current fundamental current amplitude, which show the theoretical analysis is correct compared with the protection setting values. This paper proposes the adaptive current protection scheme based on local information, which can provide a certain theoretical basis for relay protection algorithm with DG.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd