±500kV换流变压器电容隔直装置保护动作分析
Analysis on protective action of capacitive DC current blocking device for ±500kV converter transformer
Received:October 30, 2016  Revised:November 20, 2016
DOI:
中文关键词: 换流变压器  电容隔直装置  直流偏磁  饱和告警
英文关键词: converter transformer, capacitive DC current blocking device, DC magnetic bias, excitation saturation alarm
基金项目:
Author NameAffiliationE-mail
Liu Qingsong* Maintenance Test Center,CSG EHV Power Transmission Company didovo@163.com 
Wu Heng Maintenance Test Center,CSG EHV Power Transmission Company 176772663@qq.com 
Zhou Haibin Maintenance Test Center,CSG EHV Power Transmission Company 76192085@qq.com 
Deng Jun Maintenance Test Center,CSG EHV Power Transmission Company 165284950@qq.com 
zhang jinyin Maintenance DdDd Test Center, CSG EHV Power Transmission Company 405761299@qq.com 
liangchen Maintenance DdDd Test Center, CSG EHV Power Transmission Company 516067194@qq.com 
Hits: 1836
Download times: 763
中文摘要:
      为实现某换流站直流偏磁治理功能,在换流变网侧中性点加装电容隔直装置。针对一起±500kV同塔双回高压直流输电工程换流变电容隔直装置保护动作事件,介绍了该事件发生经过,分析了电容隔直装置保护动作原理和内部结构,阐述了造成本次动作事件的原因。分析表明,该电容隔直装置保护配置不合理,在直流偏磁电流较大时,用于电容器保护的晶闸管回路持续导通,导致装置失去隔离直流偏磁的效果,对换流变压器造成较大的偏磁危害。最后,针对上述问题,给出了改进后的处理措施。
英文摘要:
      In order to isolate the DC magnetic bias current, the capacitive DC current blocking device has been installed in the neutral point of converter transformers. Based on the protective action of capacitive DC current blocking device of the ±500kV HVDC project, the occurring process of the accident, the action principle of the capacitive DC current blocking device are introduced. The reason of the accident is analyzed. The analysis results show that the protection configuration of the DC blocking device is unreasonable. When the DC bias current is large, the thyristor circuit for capacitor protection is continuously turned on, which causes the device to lose DC current isolation effect. At last, the preventive measures are presented.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd