• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
(23期已送排)一种基于最近电平调制方式的MMC电压均衡改进方法
An Improved Voltage Balancing Method Based on MMC Nearest Level modulation
Received:December 22, 2016  Revised:December 29, 2016
DOI:
中文关键词: 最近电平调制  均压  积分量  电压最大偏差
英文关键词: Nearest level modulation  Voltage Balancing  Integral quantity  Maximum voltage deviation
基金项目:国家自然科学基金项目(项目编号:61174107);冶金自动化与检测技术教育部工程研究中心开放基金(项目编号:MADT201607);湖北省教育厅科学技术研究计划青年人才项目(项目编号:Q20161105)
Author NameAffiliationE-mail
Liu Zhui* College of Information Science and Engineering,Wuhan University of Science and Technology 694042668@qq.com 
Liu Zhenxing College of Information Science and Engineering,Wuhan University of Science and Technology zhenxingliu@wust.edu.cn 
Li Cui College of Information Science and Engineering,Wuhan University of Science and Technology 215850053@qq.com 
Hits: 2029
Download times: 823
中文摘要:
      最近电平调制策略是模块化多电平换流器中主要调制策略之一,在电平数较多的换流器中具有明显的优势。为保证均压效果,通常都需要实时采集各个子模块的电容电压进行排序,在实际工程中则需要大量的电压采集模块来实现。针对上述问题,本文提出了一种替换方法,即通过桥臂电流对各个子模块投入时间的积分量来进行排序,间接实现了电容电压排序的效果,这种方法可以有效的减少传感器的数量。同时,在提出的替换方法的基础上,本文引入子模块间允许的电压最大偏差,在系统输出特性允许范围的前提下,大大的降低了因排序而导致的IGBT开关频率。最后通过RT-LAB仿真平台搭建了21电平的的MMC仿真模型,对两种电压均衡方法下IGBT开关频率和子模块电容电压进行比较,仿真结果验证了所提方法的可行性及有效性。
英文摘要:
      Nearest level modulation is one of the main modulation strategies in the modular multilevel converter, which has obvious advantage in the converter with large number of voltage levels. To ensure the effect of voltage balancing, the capacitor voltages of submodules are usually required to be collected and sorted all the time, and a large number of voltage acquisition modules are needed to achieve this goal in practical engineering. In view of the above, this paper proposes a replacement method, using the integral amounts of bridge arm current to modules conduction time to sort , that indirectly realizes the effect of voltages sorting, and the method can effectively reduce the voltage sensors. Meanwhile, on the basis of the replacement method, This paper introduces the maximum voltage deviation among submodules, on the premise that the system output characteristics in allowable range, it can greatly reduce the frequency of IGBT switching caused by sorting. The model of MMC with 21 levels is realized by RT-LAB, the IGBT switching frequencies and submodule capacitance voltages under two voltage balancing methods are compared, the simulation results show that the proposed method is Feasible and effective.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd