• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
城轨牵引供电系统PWM整流器无源性功率控制研究
Research on Passivity-based Power Control of PWM Rectifier in Urban Rail Traction Power Supply System
Received:December 26, 2016  Revised:December 26, 2016
DOI:
中文关键词: 牵引供电  PWM整流器  无源控制  EL模型
英文关键词: Traction Power Supply  PWM Rectifier  EL model  Passivity-based control
基金项目:国家自然科学基金项目( 重点项目)
Author NameAffiliationE-mail
tianjiuting* Lanzhou Jiaotong University 1132569969@qq.com 
Hits: 1800
Download times: 545
中文摘要:
      现行城轨牵引供电系统多用多脉波整流的方式,但是存在谐波污染严重、能量不能双向流动的缺点,针对上述问题,文章提出了基于无源控制策略的整流器控制方式,对该种控制方式首先进行了理论推导,根据电压型整流器的主电路拓扑结构,建立了系统在两相同步旋转坐标系下的EL模型,并采用了解耦控制策略对控制器进行设计,最后将该方法用于城轨牵引供电系统中,控制整流器输出接触网(轨)的电压,并且在此基础上分析了负载扰动,机车制动,电网不平衡条件下整流器的性能,仿真结果表明,整流器具有很好的稳定性、抗干扰性,单位功率因数运行特性,对城轨牵引供电系统提供了很好的理论依据。
英文摘要:
      At present, multi-pulse rectification way is applied in urban rail traction power supply system. However, there are some disadvantages which include serious harmonic pollution and energy that cannot flow in both directions. In view of the above problems, this paper puts forward a rectifier control method based on passive control strategy. For this kind of control mode ,firstly, according to the topology of the main circuit of the voltage rectifier, the EL model of the system is established in two-phase synchronous rotating coordinate. The decoupling control strategy is used to design the controller. The strategy is used in the urban rail traction power supply system, to control the voltage of the rectifier output contact network (rail).On the basis of that, the performance of the rectifieris analyzed under load disturbance, locomotive braking and grid unbalance condition. TheSsimulationSresultsSshowSthatStheSrectifierSperformsSwellSatSSstability,Santi-jamming,SunitSpowerSfactorSoperatingScharacteristics.SThis paper provides aSgoodStheoreticalSbasisSforSurbanSrailStractionSpowerSsupplySsystem.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd