文章摘要
三电平有源电力滤波器IGBT开路故障诊断方法研究
Study on open - circuit fault diagnosis of three-level active power filter
Received:March 13, 2017  Revised:March 13, 2017
DOI:
中文关键词: 三电平有源电力滤波器  开路故障诊断  IGBT  小波包  网格搜索  支持向量机
英文关键词: three-level APF, fault diagnosis of open-circuit fault, IGBT, wavelet packet, grid Search, SVM
基金项目:河北省教育厅资助科研项目(ZD2016108);河北工业大学博士科研启动费资助项目
Author NameAffiliationE-mail
Ding Mingzhen Hebei University of Technology 634620219@qq.com 
SUN Shuguang* Hebei University of Technology sunshuguang_2000@163.com 
Hits: 1737
Download times: 1048
中文摘要:
      针对三电平中点钳位式(neutral point clamped,NPC)有源电力滤波器(active power filter,APF)中功率器件IGBT开路故障的诊断问题,提出采用小波包分析故障信号,提取各频段能量系数作为故障特征,并利用网格搜索支持向量机(support vector machine,SVM)进行分类的诊断方法。将所提方法应用于三个测试点进行测试,分别为逆变输出侧三相补偿电流、直流侧电容电压、电源侧三相电流,然后针对各信号的特点完成故障特征提取与故障类型识别,最后在谐波源三相整流桥触发角变化时进行了适应性实验,结果表明所提出的方法可分别基于三个测试点实现故障诊断,并且基于直流侧电容电压的测量方式对谐波源变化有良好的适应性。
英文摘要:
      Aiming at the problem of open-circuit fault diagnosis of IGBT in three-level neutral point clamped active power filter, this paper presents a diagnosis method which uses wavelet packet analysis fault signal, extracts the energy coefficient of each frequency band as the fault feature, and uses the grid search support vector machine to classify fault type .The proposed method is applied to three test points respectively, and the test points are the inverter output side of the three-phase compensation current, DC-side capacitor voltage, power supply side of the three-phase current. Then the fault feature extraction and fault type recognition are completed according to the characteristics of each signal. Finally, the adaptive experiment is carried out when the triggering angle of the three-phase rectifier bridge alternates. The results show that the proposed method can realize fault diagnosis based on three test points respectively, and the measurement method based on the DC side capacitor voltage has good adaptability to the alternation of the harmonic source.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd