变压器可听声诊断技术中传声器的选择
The Selection of Microphone in Power Transformer Diagnosis Technology Based on the Audible Sound
Received:March 16, 2017  Revised:March 16, 2017
DOI:
中文关键词: 变压器  传声器  可听声  数据采集  故障诊断
英文关键词: Transformer, Microphone, Audible sound, Data acquisition, Fault diagnosis
基金项目:
Author NameAffiliationE-mail
ZHAO Lihua (1. School of Electrical Engineering and Information, Sichuan University tyorika@163.com 
XuShurong (1. School of Electrical Engineering and Information, Sichuan University, 15228828198@163.com 
XIE Rongbin Guiyang Power Supply Bureau xrb123@sina.com 
XUE Jin Guiyang Power Supply Bureau 13638517436@163.com 
ZHANG Lin Guiyang Power Supply Bureau 5800163@qq.com 
Wang Zhong* (1. School of Electrical Engineering and Information, Sichuan University zhongwang1986@126.com 
Hits: 1456
Download times: 713
中文摘要:
      变压器故障检测技术研究一直是变压器研究领域的热点问题,基于可听声的变压器诊断技术是当前较新的变压器故障诊断方法。其中可听声数据采集过程是非常关键的一步,因此可听声信号采集设备的性能直接影响诊断结果的判定。本文在对常用的动圈式、电容式、驻极体电容式传声器的结构、参数性能进行分析比较的基础上,根据变压器可听声信号的特性及检测要求,推荐在变压器可听声诊断检测中采用驻极体电容式传声器。最后,采用驻极体电容式CRY333型传声器对某地区实时运行中的变压器进行数据采集,结果表明该类传声器参数性能合适,适用于变压器可听声采集。
英文摘要:
      Transformer fault detection technology research has always been a hot topic in the field of transformer research. The transformer diagnostic technology based on audible sound is a newer transformer fault diagnosis method, which audible data acquisition process is a very critical step. So the performance of the audible acoustic signal acquisition device directly affects the determination of the diagnosis result. This paper analyzes and compares the structure and performance parameters of commonly used moving coil microphones, capacitive microphones and electret condenser microphones. According to the characteristics of the audible signal of the transformer and the detection requirement, it is recommended to use the electret condenser microphone in the audible diagnosis of the transformer. Finally, an electret condenser CRY333 microphone is used to collect the data in a certain area. The results show that the performance of the microphone is suitable for transformer audible acquisition.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd