• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
一种交错并联零电流软开关双向DC/DC变换器设计*
Design of a interleaved parallel ZCT soft-switchingbidirectional DC/DC converter
Received:March 22, 2017  Revised:March 22, 2017
DOI:
中文关键词: 双向DC/DC变换器  零电流软开关  交错并联
英文关键词: bi-DC/DC  converter,ZCT  soft-switching ,interleaved  parallel
基金项目:国家自然科学基金—青年科学(51405330)
Author NameAffiliationE-mail
SONG Chaofeng* College of Electrical Power Engineering,Taiyuan University of Technology 1915710717@qq.com 
123 123 123456@qq.com 
121 121 123456@qq.com 
232 232 123456@qq.com 
323 323 123456@qq.com 
Hits: 2368
Download times: 1287
中文摘要:
      针对传统交错并联式双向DC/DC变换器在高频大功率工作时,开关管损耗大的问题,设计了一种零电流软开关交错并联式双向DC/DC变换器;通过在开关过程前后引入谐振,实现零电流开通和零电流关断,降低开关损耗;进一步分时段模态分析了Boost/Buck模式下的电路工作机理,并在其基础上提出了一种适用于特定占空比的改进型零电流软开关双向DC/DC变换器。最后,通过仿真对比,验证了所设计零电流软开关变换器能量转换效率得到了提高。
英文摘要:
      A zero-current soft-switching interleaved parallel bidirectional DC/DC converter is designed for the problem of large loss of switching tube when the traditional interleaved parallel bidirectional DC/DC converter is operated at high frequency and high power. Through the introduction of the resonant before and after the switching process to achieve zero-current turn-on and zero- current turn-off, reduce switching losses. The working mechanism of the circuit in Boost /Buck mode is analyzed by sub - time mode, and an improved zero - current soft - switching bidirectional DC/DC converter suitable for a specific duty cycle is proposed. Finally, the simulation results show that the energy conversion efficiency of the designed zero-current soft-switching converter is improved.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd