基于改进阻抗法的单相接地故障测距仿真
Simulation of transmission line to detect single line to ground fault location based on improved impedance method
Received:March 30, 2017  Revised:March 30, 2017
DOI:
中文关键词: 故障测距  单相接地故障  单端法  建模仿真
英文关键词: Fault Location, Single Line to Ground Fault, one Terminal, Modelling and Simulation
基金项目:
Author NameAffiliationE-mail
zhangjianwen China University of Mining and Technology zhang680420@sohu.com 
zhoupeng* China University of Mining and Technology zhoupeng.1992@163.com 
chenhuanxu China University of Mining and Technology 18913926891@163.com 
Hits: 1873
Download times: 809
中文摘要:
      在电力系统中高压输电线路出现故障的频率较高,在短时间内确定故障发生位置对电力公司来说显得尤为重要。精确的故障定位确保了电力系统运行的稳定性,也有助于分析特定的电网。本文通过一种有效的单端故障测距算法,利用故障电流、故障电压以及线路参数来确定故障点的位置。并通过Matlab进行建模仿真,测距结果受线路电抗大小影响。
英文摘要:
      In the power system, the frequency of transmission line failure is high, in a short time to determine the location of the failure of the power company is particularly important. Accurate fault location ensures the stability of the power system operation and also helps to analyze the specific grid. In this paper, an effective single line to ground fault location algorithm is used to determine the position of the fault point using fault current, fault voltage and line parameters. And the simulation is carried out by Matlab, that results are affected by the line reactance.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd