谐波电流扰动下配电变压器损耗计算与绝缘寿命损失评估
Calculation Distribution Transformer Loss and Insulation Life under Harmonic Currents
Received:April 20, 2017  Revised:April 20, 2017
DOI:
中文关键词: 谐波电流  空载损耗  热点温度  寿命损失
英文关键词: harmonic current, no-load loss, hot spot temperature, life loss
基金项目:
Author NameAffiliationE-mail
Zhou Weihua State Grid Hunan Electric Power Research Institute 465739651@qq.com 
Wan Dai State Grid Hunan Electric Power Research Institute 280241509@qq.com 
Ye huisheng State Grid Hunan Electric Power Research Institute yehs@hn.sgcc.com.cn 
Qi fei State Grid Hunan Electric Power Research Institute qif@hn.sgcc.com.cn 
Chen Xiaorong HUNAN XIANGDIAN TESTRESEARCH INSTITUTE CO.LTD 66998651@qq.com 
Zhao Lihua* School of Electrical Engineering and Information,Sichuan University tyorika@163.com 
Hits: 2272
Download times: 730
中文摘要:
      针对谐波电流引起配电变压器损耗增加、热老化加速、绝缘寿命下降的问题,本文提出了一种计算谐波电流扰动下变压器空载损耗的方法。通过对Yyn0和Dyn11联结的配电变压器在谐波电流扰动下的杂散损耗分析,改进了基于谐波损耗因子的变压器负载损耗计算方法,修正了热点温度计算模型。以98℃为变压器热点温度基准值,利用6℃准则修正了IEEE C57.91中的绝缘纸相对老化因子计算方法。计算及试验结果表明:变压器损耗随谐波电流畸变率增大有较大增加,造成变压器绝缘系统寿命损失,缩短变压器运行寿命。
英文摘要:
      The harmonic current will cause the loss of the distribution transformer, the acceleration of the thermal aging and the decrease of the insulation life. A method for calculating transformer core loss under harmonic current disturbance is proposed. The distribution transformer of Yyn0 and Dyn11 connection of the stray loss in harmonic current disturbance been analyzed. So the calculation method of transformer load loss based on harmonic loss factor is improved, and corrected hot spot temperature calculation model. The calculation method of relative aging factor of insulating paper in IEEE C57.91 was modified by using 6℃ criterion, the reference value of transformer hot spot temperature at 98℃. The results of calculation and experiment show that the transformer loss increases with the increase of the harmonic current distortion rate, so the life loss of transformer insulation system is shortened, and the service life of transformer is shortened.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd