文章摘要
高压直流输电直流系统保护设备现场检验方法探索
Study on On-site Test Method for DC Protection Equipment of HVDC
Received:April 24, 2017  Revised:April 24, 2017
DOI:
中文关键词: 直流系统保护设备  高压直流输电  现场定期检验  光电式电流互感器
英文关键词: DC Protection Equipment  HVDC  on-site test  optical current transformer
基金项目:国网湖南省电力公司科技项目“酒湖特高压直流接入后提升湖南电网安全稳定水平和输电能力关键技术研究”(5216A514003H);国网湖南省电力公司科技项目“基于风、水协调的湖南地区电网无功电压控制策略及应用研究”(5216A515002V)。
Author NameAffiliationE-mail
WU Jing-bo* State Grid Hunan Electric Power Corporation Science Research Institute jinbowu1112@qq.com 
CHEN Hong State Grid Hunan Electric Power Corporation Science Research Institute 626523016@qq.com 
XIONG Shangfeng State Grid Hunan Electric Power Corporation Science Research Institute 18973102190@163.com 
LIU Hai-feng State Grid Hunan Electric Power Corporation Science Research Institute lhfseawind@163.com 
HUO Si-min State Grid Hunan Electric Power Corporation huosimin@163.com 
Hits: 2250
Download times: 893
中文摘要:
      由于缺乏简单便捷又有效可行的检验方法与装置,投运后的高压直流输电直流系统保护设备一直未开展定期检验工作。这将对电网的安全稳定造成严重隐患。本文提出了一种高压直流输电直流系统保护设备现场检验方法。该方法的优点在于无需拆卸保护设备、无需解析光电转换协议、不会对电网造成不良影响、安全风险小、成本较低。研制了具备光电式电流互感器、零磁通电流互感器加量能力的高压直流保护现场检验装置。采用所提方法与装置在投运已超过十年的±500kV江城直流鹅城换流站开展了现场试点检验,验证了所提方法可行。
英文摘要:
      On-site regular test of DC protection equipment of HVDC after put into operation has not been implemented due to lack of convenient and feasible method. That is serious problem for security and stability of the power grid. This paper proposed a novel on-site test method of DC protection equipment of HVDC. The advantage of the method are that not need to remove the equipment, not explain the photoelectric conversion agreement, not cause bad influence to the grid, small security risk, and lower cost . The on-site test device for dc protection equipment of HVDC has been developed with adds quantity of optical current transformer and zero flux current transformer. Its validity was verified by on-site testing of DC Protection Equipment in Echeng convert station of Jiangling-Echeng ±500kV HVDC transmission project which in operation for more than ten years.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd