三相不平衡对配电变压器损耗影响的研究
Study on the influence of three-phase unbalance on distribution transformer loss
Received:May 04, 2017  Revised:May 04, 2017
DOI:
中文关键词: 配电变压器  三相不平衡  附加损耗  负载率  零序损耗
英文关键词: Distribution transformer, Three-phase unbalance, Additional loss ,load factor, Zero sequence loss
基金项目:国家自然科学基金项目( 51677020);教育部春晖计划项目(Z2016145);四川省电力电子节能技术与装备重点实验室开放基金(szjj2014-015)
Author NameAffiliationE-mail
Yan Zhi Qiang* Xi Hua University 895716211@qq.com 
LeiXia Xi Hua University zqy0909@126.com 
HeJianPing Xi Hua University 1538910667@qq.com 
LiuYang Development planning department,State Grid Sichuan Electric Power Company yzq900909@163.com 
Hits: 2120
Download times: 725
中文摘要:
      在配电网中,配电变压器三相不平衡运行状态普遍存在。三相不平衡会使配电变压器产生附加损耗,导致变压器局部过热,从而对变压器的绝缘寿命、带负荷能力产生很大影响。本文对常用的Dyn11和Yyn0联结方式的配电变压器建立了等效电路模型,研究其在三相不平衡状态下的损耗情况。仿真及试验结果表明,三相不平衡使变压器的损耗大幅增加,且随不平衡度的增加呈二次函数增长,不平衡度为50%时变压器损耗将增加一倍。为了保证变压器的运行安全及运行寿命,在不平衡情况下运行时,需要降低其负载率。
英文摘要:
      In the distribution network, three phase unbalanced operation of distribution transformer are widespread. Three-phase unbalanced operation will make additional loss of distribution transformer and lead to local overheating, this for the life of the transformer and load ability has a great influence. In this paper, equivalent circuit model is established for Dyn11 and Yyn0 two kinds of connection ways of distribution transformer, the loss of transformer is studied. Simulation and experimental results show that, the transformer which work under the situation that three-phase unbalanced makes loss increased dramatically, and with the increase of the unbalanced degree, the loss curve is a quadratic function. When the unbalanced degree is 50%, the wastage of the transformer will be doubled. In order to guarantee the safety and life of transformer, in the case of unbalanced runtime, needs to reduce its load factor.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd