文章摘要
三相不平衡对配电变压器带负载能力的影响研究
Study on the influence of three-phase unbalance on the load capacity of distribution transformer
Received:May 07, 2017  Revised:June 01, 2017
DOI:
中文关键词: 配电变压器  三相不平衡  相对负载系数  绕组热点温度  负载能力。
英文关键词: distribution transformer  three-phase unbalance  load factor  hot-spot temperature  load capacity
基金项目:
Author NameAffiliationE-mail
Yan Zhiqiang* Xihua University 895716211@qq.com 
Lei Xia Xihua University zqy0909@126.com 
He Jianping Xihua University 1538910667@qq.com 
Zhou Weihua State Grid Hunan Electric Power Research Institute 895716211@qq.com 
Ye Huisheng State Grid Hunan Electric Power Research Institute 895716211@qq.com 
Zhao Lihua Sichuan University tyorika@163.com 
Hits: 2322
Download times: 689
中文摘要:
      配电网中三相不平衡问题普遍存在,三相不平衡会使配电变压器单相过载导致损耗增加、热点温度升高,进而加快绝缘老化速度、降低变压器带负载能力及运行寿命。本文推导了配电变压器在三相不平衡运行时的绕组热点温度的计算模型,并基于绕组热点温度限制和容许过载倍数限制对三相不平衡时配电变压器的过载能力进行评估,最终给出了各负载类型运行区域的约束条件,为油浸式配电变压器的安全、经济运行提供了参考。
英文摘要:
      In distribution network, three-phase unbalanced operation are widespread. This will cause the problem of single-phase overload about distribution transformer, and then lead to the increase of loss and rise the hot-spot temperature. As a result, the aging rate of insulation is accelerated and has a great influence for the life of the transformer and the load capacity. In this paper, the calculation model of hot-spot temperature under off-center operation of distribution transformer is deduced. Then the overload capacity of the distribution transformer is evaluated based on the limit of hot-spot temperature and the allowable overload factor. Finally, the constraint conditions of each load type are given. This paper provides a reference for the safe and economical operation of oil immersed distribution transformers in power grid.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd