• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于VSC-HVDC的DFIG风电场低电压穿越 改进控制策略
A Improved Strategy of DFIG Wind Farm Low Votage Ride Through Based on VSC-HVDC
Received:May 17, 2017  Revised:May 17, 2017
DOI:
中文关键词: VSC-HVDC,DFIG,低电压穿越,无功功率分配
英文关键词: VSC-HVDC, DFIG, Low votage ride through, Reactive power distribution
基金项目:
Author NameAffiliationE-mail
Li Yanqing Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense,North China Electric Power University,baoding,071003 1084829182@qq.com 
Shi Yiming* Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense,North China Electric Power University,baoding,071003 1084829182@qq.com 
Hits: 1710
Download times: 609
中文摘要:
      提出了一种适用于VSC-HVDC系统并网DFIG风电场的低电压穿越控制策略。根据DFIG机组和VSC模型,计算了无功功率极限。传统的Crowbar电路在系统故障时将转子侧换流器(RSC)进行短路,使DFIG风电场失去对系统提供无功功率的能力。提出了改进控制策略,根据电网故障严重程度控制Crowbar电路的动作。根据风电场和VSC-HVDC系统各个换流器的功率极限,提出了输电系统风电场侧换流器(WFVSC)优先的无功功率分配策略,根据电网的无功缺额分配换流器之间的无功出力。使用MATLAB/Simulink平台搭建了仿真系统,对改进控制策略进行了验证。
英文摘要:
      A control strategy for DFIG wind farm low votage ride through based on VSC-HVDC is proposed.In accordance with the model of DFIG and VSC,the limitation of reactive power is calculate. When the system break down, traditional Crowbar circuit will make a short circuit in RSC which make DIFG unable to provide reactive power to the system.A improved control strategy is proposed so that the Crowbar circuit will act according to the level of the fault. In consideration of the power limitation of each convertor station, the strategy of reactive power distribution is put up which will allot the reactive power output according to the reactive power gaps of the system.A model is established using MATLAB/Simulink to verify the improved strategy.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd