• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于LDPC的改进G3-PLC物理层规范模型
Improved model of G3-PLC physical layer specification based on LDPC
Received:June 04, 2017  Revised:June 04, 2017
DOI:
中文关键词: 电力线  信道编码  G3-PLC标准  LDPC
英文关键词: power line communication, channel coding, G3-PLC standard, LDPC
基金项目:国家自然科学基金项目( 重点项目)
Author NameAffiliationE-mail
zhaolong* North China Electric Power University HBDLDXZL@163.com 
Hu Zhengwei North China Electric Power University hzwwizard@hotmail.com 
Xie Zhiyuan North China Electric Power University zhiyuanxie@263.net 
Hits: 1881
Download times: 756
中文摘要:
      为了提高电力线通信的可靠性,对G3-PLC物理层规范进行了改进,给出了一种基于LDPC编码/译码的G3-PLC模型。改进模型将G3-PLC物理层规范中的RS编码/译码功能模块分别替换为LDPC编码/译码功能模块。结合G3-PLC物理层规范,实现了面向该规范的LDPC编码与译码功能。在Simulink环境分别建立了G3-PLC物理层规范模型和改进的物理层规范模型,分析验证了所提改进模型的有效性。改进模型为LDPC应用于基于G3-PLC规范的系统设计提供了一定参考。
英文摘要:
      In order to improve the reliability of power line communication , a improved model of G3-PLC physical layer specification based on LDPC encoding / decoding were proposed. In the improved model, the RS encoding / decoding function modules in the G3-PLC physical layer specification were replaced by the LDPC encoding / decoding function modules respectively. According to the G3-PLC physical layer specification, the LDPC encoding and decoding function were realized. The G3-PLC physical layer specification model and the improved physical layer specification model were built respectively in the Simulink software, the validity of the improved model were confirmed. The improved model provides a reference for the application of LDPC to the system design based on G3-PLC specification.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd