• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
接力式馈线自动化测试方法研究与应用
Research and Implementation of the Data Relay Method for Feeder Automation Test
Received:June 05, 2017  Revised:June 05, 2017
DOI:
中文关键词: PSCAD/EMTDC  馈线自动化  接力式  仿真测试  混合编程
英文关键词: PSCAD/EMTDC, feeder automation, data relay, simulation test, mixed-language programming
基金项目:
Author NameAffiliationE-mail
Xu Changbao Electric Power Research Institute of Guizhou Power Grid Co,Ltd 13985494586@163.com 
Wang Zheng* Shanghai Wiscom Sunest Power Technology Co. Ltd jinglingshushu@163.com 
Xiao Xiaobing Electric Power Research Institute of Guizhou Power Grid Co,Ltd xiaoxiaobing1986@163.com 
Ling Wanshui Shanghai Wiscom Sunest Power Technology Co. Ltd wsling@wiscom.com.cn 
Wang Feng Shanghai Wiscom Sunest Power Technology Co. Ltd wangfeng@wiscom.com.cn 
Hits: 1893
Download times: 1695
中文摘要:
      在现有馈线自动化仿真测试方案的基础上,引入电力系统暂态仿真软件PSCAD/EMTDC,通过PSCAD/EMTDC接口模块开发实现了其与现有馈线自动化测试平台的数据同步,进而构成了实时闭环的高保真仿真测试系统。通过PSCAD/EMTDC仿真得到的电流电压可以实时地注入到配电自动化主站或配电终端中,同时被测系统的开关状态也同步地反馈到PSCAD/EMTDC中。新的测试方法可以逼真地模拟配网系统各种运行工况和故障形态,尤其是实现了对接地故障的仿真测试。应用新的测试方法对智能分布式馈线自动化系统进行了测试,实际验证了新方法的可行性。
英文摘要:
      Based on existing test solutions of feeder automation, the transient simulation software PSCAD/EMTDC is employed to integrate with existing test platform to form a closed-loop test bench by the developing of user defined function modules. To streamline data exchange among PSCAD/EMTDC, test platform and DTU, a data relay method is used. The currents and voltages obtained from PSCAD/EMTDC can be injected into master station or DTU, at the same time the state of switches of tested distribution network shall be updated in PSCAD/EMTDC accordingly. The new test method could simulate various operation conditions and faults, especially for the earth fault. The new method has been applied to a testing distributed FA system, the results demonstrate the feasibility of this method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd