• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
利用广域测量系统的振荡中心定位及其应用
Location of Oscillation Center Using Wide Area Measurement System and Its Application
Received:June 28, 2017  Revised:June 28, 2017
DOI:
中文关键词: 广域测量系统  振荡中心  解列控制  大区域电网
英文关键词: Wide area measurement system, Oscillation center, Splitting control, Large area grid
基金项目:国家自然科学基金项目( 重点项目)
Author NameAffiliationE-mail
Yang Yue* North China Electric Power University, Baoding 2648223660@qq.com 
Gu Xueping North China Electric Power University, Baoding xpgu@ncepu.edu.cn 
Wang Tao North China Electric Power University, Baoding wtwxx@126.com 
Hits: 1418
Download times: 1290
中文摘要:
      针对电势幅值不等、全系统阻抗不均时振荡中心的定位问题,本文提出一种利用广域测量系统的振荡中心定位新方法。当系统故障时,采用Ucosφ判据判别系统是否发生失步振荡,失步后利用广域测量系统获取电网全局动态实时信息,根据电势向量、母线电压向量及其差向量之间的夹角确定振荡中心位置,根据系统电压分布几何关系计算振荡中心电压。结合同调机群与功率不平衡度,给出了大区域互联电网的解列控制流程。实际算例表明,本文方法能够跟踪振荡中心的迁移,准确定位振荡中心,为后续解列控制奠定基础。
英文摘要:
      A new method of locating the oscillation center using the wide area measurement system is proposed in this paper, which aimed at the problem of oscillation center positioning of the system whose amplitude of the potential is not equal and the whole system impedance is not uniform. When the system failure, the Ucosφ criterion is exploited to judge whether the system begin to oscillate. The wide-area measurement system is used to obtain the global real-time information of the grid, the oscillation center is determined according to the angle among the potential vector, the bus voltage vector and their difference vector. Then the oscillation center voltage is calculated using the geometry of the system voltage distribution. Combined with the system coherent generators and power imbalance, the business processes of splitting control is elaborated. The actual example shows that the method can track the migration of the oscillation center and provide the accurate position of the oscillation center.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd