基于MMC的电力电子变压器保护系统研究*
Research on protection system for MMC based power electronic transformer
Received:July 06, 2017  Revised:July 06, 2017
DOI:
中文关键词: 电力电子变压器  故障分析  保护配置  过电压  过电流
英文关键词: power electronic transformer, fault analysis, protection configuration, overvoltage, overcurrent
基金项目:北京市自然科学基金(3172036)
Author NameAffiliationE-mail
Zhou Tingdong* State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University zhoutingdong502@163.com 
Xu Yonghai State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University yonghaixu@263.net 
Hits: 1477
Download times: 470
中文摘要:
      介绍了基于MMC的电力电子变压器主电路拓扑及运行原理;对其可能出现的故障类型配置了相应的故障量测点以及保护方法;对MMC型电力电子变压器中存在的特殊故障及保护问题进行了详细分析,包括交流输入侧接地电阻的选择对交流侧接地故障和直流侧单极接地故障的影响,直流双极短路故障发生后采用具有直流故障电流抑制能力的箝位双子模块替换半桥子模块之后产生的过电压问题,以及电力电子变压器隔离级串联电容迅速放电产生冲击过电流问题;针对以上问题提出了相应的保护应对策略,并通过PSCAD仿真证明了所提策略的正确性和有效性。
英文摘要:
      The main circuit topology and operation principle of MMC based power electronic transformer were introduced. The corresponding fault measurement points and protection methods were also provided for the types of faults that may occur. The special faults and protections in the MMC based power electronic transformer were analyzed in detail, including the impact of the selected grounding resistance on AC input side grounding fault and DC side single pole grounding fault, the overvoltage generated by clamp dual sub module with the DC fault current suppression capability instead of the half bridge sub module after the DC pole to pole short-circuit fault occurred, and the rapidly discharging problem caused by a series of capacitors in the isolated stage of power electronic transformer. In view of the above problems, the corresponding protection strategies were put forward, and the correctness and effectiveness of the proposed method were proved by PSCAD simulation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd