之字形自耦变压器移相角影响分析及Matlab仿真
Phase-shift angle analysis on zigzag autotransformer and Matlab simulation
Received:July 17, 2017  Revised:July 17, 2017
DOI:
中文关键词: 之字形自耦变压器  移相角  12脉波整流  升压变压器  仿真测试
英文关键词: Zigzag  autotransformer, Phase-shift  angle, 12-pulse  rectifier, Step-up  transformer, Simulation  analysis
基金项目:甘肃省自然基金资助项目(145RJZA098);
Author NameAffiliationE-mail
wangjiarong* engineering and automation, Lanzhou Jiaotong University wjr0216364@163.com 
ChenXiaoQiang engineering and automation, Lanzhou Jiaotong University xqchen@mail.lzjtu.cn 
Hits: 1971
Download times: 761
中文摘要:
      自耦变压器较传统隔离式变压器在一定程度上减小了整流系统的体积,同时自耦变压器由于其对称的设计结构使其在消除谐波、降低负载电压纹波系数方面也优于传统隔离式变压器。为适应升压场合,优化了传统移相角。分析了移相角对12脉波整流系统输入侧电流和负载电压的影响,及对12脉波整流系统之字形自耦变压器等效容量和平衡电抗器等效容量的影响。给出了新的移相角,使之字形自耦变压器能适用于二次侧电压稍大于一次侧电压的升压场合。仿真结果表明,在同匝比条件下,之字形自耦变压器较传统隔离式移相变压器容量小33%且结构对称。
英文摘要:
      To some extent, auto-connected transformer reduced the volume of rectifier compared with traditional isolated transformer. Meanwhile auto-connected transformer is better than traditional isolated transformer in harmonic reduction and lower load voltage ripple coefficient due to its asymmetrical structure. In terms of zigzag auto-connected transformer, to adapt to step-up occasion, traditional phase-shift angle is optimized. The effect of phase-shift angle on current and output voltage of load and on the equivalent KVA rating of autotransformer and interphase reactor are carried out. A novel phase-shift angle for zigzag auto-connected transformer is proposed to satisfy step-up voltage situation. The results of simulation suggest that equivalent KVA rating of zigzag auto-connected transformer with a novel phase-shift angle is 33% smaller than traditional isolated transformer under the same turn ratio and is more symmetrical than traditional isolated rectifier.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd