• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于分布式光伏逆变器的电能质量综合补偿装置
Comprehensive Compensation Device for Power Quality Based on Distributed Photovoltaic Inverter
Received:July 24, 2017  Revised:July 24, 2017
DOI:
中文关键词: 光伏逆变器  谐波  无功指令  不平衡分量  DG-FACTS
英文关键词: photovoltaic  inverter, harmonic, reactive  power command, unbalanced  component, DG-FACTS
基金项目:
Author NameAffiliationE-mail
TAO Liang* School of Electrical Engineering,Wuhan University 122593639@qq.com 
CHENG Junzhao Yunnan Power Grid Co,Ltd Grid Planning Research Center chengjunzhao@126.com 
WANG Wenxi Yunnan Power Grid Co,Ltd Grid Planning Research Center wangwenxi@im.yn.csg 
GONG Jinwu School of Electrical Engineering,Wuhan University gongjinwu@whu.edu.cn 
Hits: 1435
Download times: 488
中文摘要:
      为解决配电网中日益突出的谐波超标、电压偏差、三相不平衡等电能质量问题,提出了一种利用分布式光伏逆变器的冗余容量实现无功、谐波、负序的综合补偿功能的控制策略,研究了一种在不影响正常光伏逆变器并网发电的情况下实现电能质量综合治理(DG-FACTS)的方法。首先分析了适用于DG-FACTS的谐波检测、无功指令提取及不平衡分量检测的算法,然后研究了指令合成及电流跟踪控制算法,并通过Matlab/Simulink仿真验证了DG-FACTS功能的可行性。仿真结果表明:所提出的基于分布式光伏逆变器的电能质量综合补偿方法具有较好的实用性。
英文摘要:
      In order to solve the problem of power quality, such as excessive harmonics, voltage deviation and three-phase imbalance in distribution network, This paper presents a control strategy based on the redundant capacity of the distributed PV inverter to realize the comprehensive compensation function of reactive power, harmonics and negative sequence. A method is proposed to realize the control of the inverter without affecting the power generation of the normal PV inverter Power Quality Integrated Management (DG-FACTS) method. Firstly, the algorithm of harmonic detection, reactive power instruction extraction and unbalanced component detection for DG-FACTS is analyzed. Then, the instruction synthesis and current tracking control algorithm is studied, and the function of DG-FACTS is verified by simulation based on Matlab/Simulink. Results of simulation show that the proposed method of comprehensive compensation of power quality based on distributed PV inverter has good practicability.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd