• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
含逆变型分布式电源的小电阻接地方式 配电网单相接地故障分析
Earth fault analysis on low resistance grounded distribution network with inverter interfaced distribution generation
Received:August 18, 2017  Revised:August 18, 2017
DOI:
中文关键词: 小电阻接地配电网  逆变型分布式电源  单相接地故障  中性点接地方式  故障电流
英文关键词: low resistance grounded distribution network  inverter interfaced distribution generator  earth fault  neutral grounding mode  fault current
基金项目:国家自然科学基金项目( 重点项目)
Author NameAffiliationE-mail
yanghao* North China Electric Power University 1119844306@qq.com 
xuyuqin North China Electric Power University 1119844306@qq.com 
lipeng North China Electric Power University 1119844306@qq.com 
Hits: 1377
Download times: 708
中文摘要:
      针对小电阻接地方式配电网,根据IIDG的控制策略结合对称分量法,建立IIDG并网后其上游侧和下游侧的单相接地故障分析模型,对 IIDG并网变压器在不同接地方式下的故障点电流,主网侧和IIDG侧的各序和各相电流分别进行了分析,最后利用PSCAD/EMTDC搭建故障仿真模型,验证了分析的正确性,为并网变压器接地方式的选择及继电保护的配置提供依据。
英文摘要:
      Based on a low resistance grounded distribution network, according to the control strategy of IIDG combining symmetrical component method, establish IIDG grid after its upstream and downstream side of single-phase earth fault analysis model, the IIDG interconnection transformer fault point current under different grounding method, main side and IIDG side of each sequence and each phase current are analyzed respectively, and finally using PSCAD/EMTDC builds the fault simulation model, verify the validity of the analysis, for the interconnection transformer grounding method provides the basis for selection and configuration of protection.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd