• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
电力线信道系统噪声的建模方法研究
Research on Noise Modeling Method in Power Line Channel System
Received:August 21, 2017  Revised:August 21, 2017
DOI:
中文关键词: 电力线信道  电弧故障  噪声建模  分数阶滤波  数据驱动。
英文关键词: Power  line channel, arc  fault, noise  modeling, fractional-order  filter, data-driven
基金项目:国家自然科学基金资助项目(51277093)
Author NameAffiliationE-mail
Hu Suyang College of Automation Engineering,Nanjing University of Aeronautics and Astronautics husuyang@nuaa.edu.cn 
Wang Li* College of Automation Engineering,Nanjing University of Aeronautics and Astronautics liwang@nuaa.edu.cn 
Yang Shanshui College of Automation Engineering,Nanjing University of Aeronautics and Astronautics yshanshui@nuaa.edu.cn 
Hits: 1218
Download times: 479
中文摘要:
      实际飞机电缆系统存在信道环境恶劣、噪声特性复杂的问题,对系统的正常通信及故障检测造成较大的干扰。本文在对典型电力线噪声进行分类并分析其不同特性的基础上,针对电力线中常发生的电弧故障,提出基于分数阶滤波器的电弧噪声建模方法,以及基于数据驱动的电弧噪声模型参数确定方法,与典型电力线噪声相结合,建立更加完善、准确的电力线信道系统噪声模型。通过仿真和实验结果验证了模型的准确性,为后续开展电力线故障诊断技术的深入研究提供参考。
英文摘要:
      There are problems of complicated channel environment and complex noise characteristics in the aircraft cable system, which has caused great interference to the normal communication and fault detection of the system. In this paper, based on the classification of typical power line channel noise and its different characteristics, an arc noise modeling method based on fractional-order filter is proposed, and the parameter determination method of arc noise model based on data-driven is proposed, that combined with the typical power line noise, building a more complete and accurate power line channel system noise model. The accuracy of the model is verified by the simulation and experimental results, which can provide a reference for the further study of the power line fault diagnosis technology.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd