消弧线圈分散补偿单相接地故障运行特性分析
Analysis of single - phase - to - ground fault operation characteristic of arc suppression coil dispersion compensation
Received:August 27, 2017  Revised:August 27, 2017
DOI:
中文关键词: 消弧线圈  分散补偿  接地残流  弧光过电压
英文关键词: 
基金项目:
Author NameAffiliationE-mail
Lin Hai* North China Electric Power University 617512248@qq.com 
Liang Zhirui North China Electric Power University zhiruil@sohu.com 
Hits: 1488
Download times: 582
中文摘要:
      为应对配电网电容电流剧增给增容改造带来的困难,文章提出了消弧线圈分散补偿接地方式,并对消弧线圈分散补偿接地系统的运行特性进行分析和研究。首先阐述了分散补偿接地系统的原理及特点,分析了分散补偿消弧线圈的调节原理和安装位置;然后讨论了分散补偿消弧线圈的安装位置、不同容量分配和不同过渡电阻对故障点接地残流的影响;最后对分散补偿接地系统的弧光过电压进行分析。通过Matlab/Simulink建模和仿真,结果表明消弧线圈分散补偿能有效补偿故障接地电流并满足残流要求,发生间歇性故障接地时消弧线圈分散补偿也能很好地抑制弧光过电压至较低水平。
英文摘要:
      In order to solve the problems caused by the increase of capacitor current in distribution network, the decentralized compensation grounding method of arc suppression coil is put forward, and the running characteristics of arc suppression coil distributed compensation grounding system are analyzed and studied. Firstly, the principle and characteristics of decentralized compensation grounding system are expounded, and the principle and installation method of decentralized compensated arc suppression coil are analyzed. Then, the influence of decentralized compensation arc suppression coil installation position and different capacity distribution on ground residual flow under different transition resistance is discussed.Fanally, the overvoltage of the distributed compensation grounding system is analyzed.Through Matlab / Simulink simulation,the result shows that the decentralized compensation of the arc suppression coil and the traditional centralized compensation can effectively compensate the fault ground current and meet the residual flow requirements,and the decentralized compensation of the arc suppression coil can also suppress the arc overvoltage well.#$NLKeywords: arc suppression coil; decentralized compensation; ground residual flow; arc overvoltage
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd