• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
具备VSG特征并网变流器的预同步及主动孤岛判别方法研究
Research on Pre-synchronization and Islanding identification method of Converter with VSG characteristics
Received:August 29, 2017  Revised:August 29, 2017
DOI:
中文关键词: 虚拟同步发电机  并离网切换 主动孤岛判别  预同步
英文关键词: VSG, Grid-connected/islanded  transition, Islanding  identification, Pre-synchronization
基金项目:
Author NameAffiliationE-mail
Zhai Denghui* XUJI Group Corporation zdh-11123@163.com 
Wangpeng STATE GRID HENAN ELECTRIC POWER COMPANY electric power research institute w-fsfe@163.com 
Xinjun STATE GRID HENAN ELECTRIC POWER COMPANY zhengzhou power supply company xinjun@ha.sgcc.com.cn 
Ren Zhihang XUJI Group Corporation 13703742226@139.com 
YangDonghai XUJI Group Corporation Ydh2713@163.com 
Hits: 1537
Download times: 473
中文摘要:
      分析研究VSG数学模型,针对具备VSG特征的并网变流器,研究其预同步及主动孤岛判别方法,提出一种基于逐步追踪思想的预同步控制和基于电网电压自扰动的主动孤岛判别方法;其中预同步控制根据两侧系统电压幅值差和相位差,按照一定步长调节变流器侧输出电压的幅值和相位,进而追踪逼近电网侧电压幅值和相位,当差值在很小范围内时,将电网电压的幅值和相位作为变流器输出侧电压幅值和相位的参考值,合闸实现离网到并网的“零”冲击;主动孤岛判别是将电网侧电压幅值以微小步长进行负扰动,扰动后的值作为变流器输出侧电压幅值的参考给定,若电网连接,则扰动基本无影响,若电网断开,因扰动使得电压持续减小,最终判别出孤岛现象。通过MATLAB仿真分析,验证了所提方法的有效性和可行性。
英文摘要:
      The VSG mathematical model is analyzed,in view of the grid-connected converter with VSG characteristics, this paper is focused on the analysis of the pre-synchronization based on the step-by-step idea and active island method based on the disturbance of grid voltage. According to difference value between the system voltage amplitude and phase on both sides, voltage amplitude and phase of the converter is adjusted by a certain step in order to close to the grid side. When differences are in a small scope, grid voltage amplitude and phase are used as the reference value the converter, thus converter switching from off-grid mode to grid-connected mode with zero impact interconnection. According to active islanding identification of converter with VSG characteristics, the grid voltage amplitude is perturbed by small step. The new grid voltage amplitude is given as reference for the voltage of converter. If the grid is connected, the disturbance has no effect. If the grid is disconnected, voltage will continue to decrease, island is identified eventually. Through MATLAB simulation analysis, the feasibility and effectiveness of the proposed method is verified.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd