文章摘要
特高压直流换流站二次设备回路传导电压干扰特性研究
Research on the conducted voltage interference in the secondary circuit of an UHVDC converter station
Received:September 01, 2017  Revised:September 01, 2017
DOI:
中文关键词: 电容式电压互感器  特高压直流输电  二次设备回路  传导电压干扰  
英文关键词: Capacitor Voltage Transformer  UHVDC  Secondary equipment model  Conducted voltage interference  
基金项目:
Author NameAffiliationE-mail
Wu Hao* Test and Maintenance Center, CSG EHV Power Transmission Company 14383292@qq.com 
Li Hongyuan Test and Maintenance Center, CSG EHV Power Transmission Company 2234861084@qq.com 
Liu Jianhong Guangzhou Power Supply Bureau Co., Ltd. 799011497@qq.com 
Hits: 1390
Download times: 748
中文摘要:
      准确分析特高压直流换流站二次设备回路电磁干扰特性是制定相关防护措施的前提和依据。本文以某±800kV特高压直流输电工程为对象,分别建立了换流阀、换流变、平波电抗器等一次回路元件的宽频等效模型,进而得出了一次回路传导电压干扰特性,结合电容式电压互感器和二次电缆的宽频等效模型,分析了各种工况下二次设备回路的传导电压干扰特性,并分析了电缆长度、负载率等因素的影响。
英文摘要:
      Accurate analysis of the electromagnetic interference characteristics in the secondary equipment circuit in an UHVDC converter station is the premise and basis for formulating the protection measures. The broadband equivalent models of the main elements of a ±800kV UHVDC converter station, such as the converter valve, converter transformer and smoothing reactor are built in this paper, and the conducted voltage characteristics of the primary circuit are obtained accordingly. Combined with the broadband equivalent model of Capacitor Voltage Transformer and secondary circuit cables, the conducted voltage characteristics in the secondary equipment circuit under different operation modes are researched, the influence of the cable length and burden rate are studied.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd