• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
真型多状态GIS局部放电UHF信号源研究*
Research on UHF Signal Source of Partial Discharge in True Multi - State
Received:September 18, 2017  Revised:September 18, 2017
DOI:
中文关键词: 真型  多状态  GIS  PD  UHF  信号源
英文关键词: true  scale, multi - State, GIS, PD, UHF, signal  source
基金项目:
Author NameAffiliationE-mail
WU Jian-rong Electric Power Science Research Institute,Guizhou Power Grid Co,Ltd 407452495@qq.com 
YANG Tao Electric Power Science Research Institute,Guizhou Power Grid Co,Ltd yang_tao17@163.com 
ZHANG Guo-zhi* Wuhan University youxzgz@163.com 
ZHANG Xiao-xing Wuhan University xiaoxing.zhang@outlook.com 
ZHANG Jun Chongqing University 874058721@qq.com 
Hits: 1840
Download times: 533
中文摘要:
      针对电网公司广泛装配的特高频(UHF)局部放电检测系统无法进行有效性校验问题,本文以GIS典型缺陷类型下的UHF信号谱图为基础,对不同缺陷类型下不同放电强度的UHF谱图信号分别进行特征提取和优化,并根据该特征对UHF谱图信号进行0-50V范围内的编码优化,据此设计出了能够模拟多种典型绝缘缺陷下不同放电程度的真型多状态GIS局部放电信号源,并进行了实验测试,测试效果良好。
英文摘要:
      For the ultra-high frequency (UHF) PD detection system which is widely assembled by Power Grid Corp, it is always impossible to verify the validity. Based on the UHF signal spectrum of GIS typical defect type, the feature extraction and optimization of UHF spectrum signals under different defect types are carried out respectively. And according to this characteristic, the UHF signal spectrum is optimized in 0-50V range. A true GIS PD signal source is designed to simulate the UHF signals of various typical insulation faults and tested, the test result is good, and it shows a good application prospect in the checkout of the UHF detection system in GIS.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd