HVDC单极闭锁暂态特性的桥差保护动作分析
Analysis of Bridge Differential Protection Action in Unipolar Blocking Transient Characteristics of HVDC Transmission System
Received:October 18, 2017  Revised:November 14, 2017
DOI:
中文关键词: 换流变压器  单极闭锁  桥差保护  暂态响应特性
英文关键词: converter transformer, unipolar blocking, bridge differential protection, transient response characteristics
基金项目:中国南方电网公司科技项目(CGYKJXM00000001)
Author NameAffiliationE-mail
Peng Guangqiang Maintenance Test Center,CSG EHV Power Transmission Company pengguang_qiang@163.com 
Liu Qingsong* Maintenance Test Center,CSG EHV Power Transmission Company didovo@163.com 
Chen Wei Maintenance Test Center,CSG EHV Power Transmission Company 47107843@qq.com 
Wu Jiyang Maintenance Test Center,CSG EHV Power Transmission Company wujy0451@163.com 
Wu Heng Maintenance Test Center,CSG EHV Power Transmission Company 176772663@qq.com 
Deng Jun Maintenance Test Center,CSG EHV Power Transmission Company 165284950@qq.com 
Hits: 1247
Download times: 524
中文摘要:
      针对高肇直流工程一起桥差保护动作导致单极闭锁的紧急停运事件,介绍了该事件发生的经过和保护动作原理,研究了直流输电工程双极转单极大地运行瞬间换流变压器的暂态响应特性,阐述了造成本次动作时间的根本原因。研究结果表明,在系统的零序等值回路里,零序电压的变化或零序阻抗的变化,是导致中性点零序电流出现暂态偏置的原因。在零序电流偏置的暂态过程中,接地极线路近区遭受雷击,导致入地电流续流并通过近区大地进入换流站地网,换流变压器出现直流偏磁饱和,暂态传变特性导致换流器Y桥和D桥电流差过大,在200ms后达到桥差保护动作条件,换流器桥差保护动作。最后,针对上述问题,给出了整改措施,并起到了良好的工程应用效果。
英文摘要:
      This paper introduces the the action principle of the bridge differential protection of HVDC transmission system, and studies the transient response characteristics of the converter transformer from bipolar operation to unipolar operation. The reason of the accident is analyzed. The analysis results show that in the zero sequence equivalent circuit of the system, the change of the zero sequence voltage or the change of the zero sequence impedance is the reason for the transient bias of the neutral zero sequence current. In the transient process of the zero sequence current bias, the grounding transmission line is subjected to lightning strikes in the near area, resulting in the earthing current which flows into the converter station earthing network. The converter transformer has DC magnetic bias saturation. The variable transient transmission characteristics of converter transformers, result in the differenct currents of converter Y bridge and converter D bridge, which cause the converter bridge differential protection action after 200ms. Finally, the corrective measures have been given, and have a good engineering effect.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd