风电机组变流器电流谐波水平案例分析
Case study on current harmonics level of 1.5 MW direct-drive wind turbines
Received:October 19, 2017  Revised:October 19, 2017
DOI:
中文关键词: 直驱风电机组  变流器  电流谐波  间谐波  高频分量
英文关键词: direct-drive  wind turbines,converter,current  harmonics,interharmonics,higher  frequency components
基金项目:自治区重点实验室开放课题(2016D03021);自治区重点研发任务(2016B02019)
Author NameAffiliationE-mail
ZHAO Zihang* The College of Electrical Engineering,Xinjiang University zzhxju@163.com 
WANG Haiyun The College of Electrical Engineering,Xinjiang University 327028229@qq.com 
TANG Xinan Beijing Goldwind Science DdDd Creation Wind Power Equipment Co., Ltd. tangxinan@goldwind.com.cn 
WANG Jia Beijing Goldwind Science DdDd Creation Wind Power Equipment Co., Ltd. wangjia1@goldwind.com.cn 
Hits: 1690
Download times: 1203
中文摘要:
      直驱机组全功率变流器的使用,一定程度上影响了机组馈入电网的电能质量。针对两类1.5MW直驱并网风力发电机组,从整机角度上描述了机组配置,比较了I型变流器、II型变流器的拓扑结构与控制原理。依据IEC标准检测方法,通过现场实测,对比研究了这两类机组电流谐波、间谐波、高频分量的释放水平及特征。结果表明,变流I型、变流II型机组电流谐波释放水平均符合并网要求,变流I型机组电流谐波水平2.52%低于变流II型机组3.44%。
英文摘要:
      The use of full size power converter for direct-drive wind turbines has an impact on the power quality of grid. This paper presented the configuration of two types of 1.5MW permanent magnet direct drive grid-connected wind turbines. The topologies and control strategies of converter I and converter II system are also compared. According to IEC measurement methods, the emission levels and characteristics of current harmonics, interharmonics and higher frequency components are measured and studied in field tests. The test results show that the emissions of current harmonics is in compliance with the grid code requirements, and the current harmonics level of wind turbine with converter I is 2.52% lower than 3.44% of wind turbine with converter II.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd