微电网线路保护方案优化研究
Research on Optimization of Microgrid Line Protection Scheme
Received:November 07, 2017  Revised:November 07, 2017
DOI:
中文关键词: 微电网  线路保护  继电器  通信系统
英文关键词: Micro-grid  Line protection  relay  communication system
基金项目:
Author NameAffiliationE-mail
luolingtong* North China Electric Power University hdlingtong@126.com 
YangMingyu North China Electric Power University yangmy1026@hotmai.com 
MengHang North China Electric Power University 8070552244@qq.com 
Hits: 1852
Download times: 705
中文摘要:
      针对微电网在并网和孤岛运行状态下,故障电流差距较大,使得保护识别故障和上下级线路保护之间的选择性配合较为困难。文中考虑传统保护整定配合困难和无法同时满足两种运行模式下的微网的上下级线路跳闸时间选择性或速动性要求,提出了并网和孤岛状态下保护采用正序电流识别故障电流方向并采用过电流协调保护的启动条件。其次提出基于通信系统实现线路上下级保护的自适应整定延时和阶梯形的后备延时作为选择性方案。对微源较多的辐射型微网线路保护,通信系统以公共连接点为最高级,各条线路级别依次下降,其中下级延时信号向上级传输。文中通过MATLAB/Simulink环境中构建了典型的辐射型微电网算例,通过典型工况验证了该方案的有效性。
英文摘要:
      As the micro-grid operating in the grid and island conditions, the fault current gap is large, which making it difficult to identify and realize a better coordination between the upper and lower lines. In this paper, it is necessary to consider the requirements of the traditional protection setting and the difficulty of setting the upper and lower line tripping time of the microgrid in the two modes of operation. In this way, it is proposed to use the positive sequence current to identify the fault current direction and adopt the overcurrent coordination protection condition under the grid and island state protection. Secondly, this paper proposes an adaptive tuning delay and stepped backup delay based on the communication system to realize the upper and lower protection of the line as the selective scheme. For the more micro-radiation micro-network, the communication system to the public connection point for the most advanced, each line level in turn decline, which subordinate delay signal to the higher level transmission. In the MATLAB / Simulink environment, a typical example of radiation microgrid is constructed, and the effectiveness of the comprehensive protection scheme is verified by typical working conditions.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd