• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
典型小电流接地故障实例及暂态选线分析
Analysis of Typical Single-phase Earth Faults and Transient Faulty Feeder Selection Technology in the Non-solidly Earthed System
Received:November 08, 2017  Revised:November 08, 2017
DOI:
中文关键词: 小电流接地系统  单相接地故障  典型实例  暂态选线
英文关键词: non-solidly earthed network  single-phase grounding fault  typical field faults  transient faulty feeder selection
基金项目:国家自然科学基金项目(51477184)
Author NameAffiliationE-mail
Li Tianyou State Grid Fujian Electric Power Co,Ltd lmko@qq.com 
Wang Chao Shandong Kehui Power Automation Co wangc@kehui.cn 
Chen Minwei State Grid Fujian Electric Power Research Institute 397215047@qq.com 
Xue Yongduan* Shandong Kehui Power Automation Co lmko@qq.com 
Huang Jianye State Grid Fujian Electric Power Research Institute 18650760703@163.com 
Hits: 2035
Download times: 978
中文摘要:
      目前对小电流接地故障特征的理论分析已较完善,但缺乏对现场典型小电流接地故障实例的认识及利用典型实例对选线技术的验证。本文介绍了暂态选线方法及原理,并根据现场选线装置实际记录的典型故障实例波形,分析并总结了典型接地故障的发生原因、故障特征及对暂态选线结果的影响。通过对现场典型小电流接地故障实例的分析与总结,有利于提高对现场典型接地故障特征的认识,验证暂态选线装置的可靠性。
英文摘要:
      The fault characteristic theoretical analysis in the non-solidly earthed network is almost complete. But the understanding of the typical field faults and the verification of the faulty feeder selection technologies by field faults data are in great demand. The transient faulty feeder selection technologies are introduced. According to the typical field faults waveforms, the cause of the typical field faults, the fault characteristic and the effect on the result of the transient faulty feeder selection technologies are analyzed. By analyzing and summarizing the typical field faults, the understanding of the typical field faults can be improved. The reliability of the transient faulty feeder selection technologies can be verified.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd