• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于混合H2/H∞控制理论的交直流并联系统机网阻尼协调控制
A Coordinated Damping Control of Generator and Gird in AC/DC Parallel Power System Based on Mixed H2/H∞ Control Method
Received:November 30, 2017  Revised:November 30, 2017
DOI:
中文关键词: 交直流并联系统  低频振荡  鲁棒控制  附加阻尼控制;机网协调控制
英文关键词: Parallel AC/DC power system  Low frequency oscillation  Robust control  Supplementary damping control  Coordinated control of generator and gird
基金项目:国家电网公司科技项目(SGNXDK00BGJS1600021)
Author NameAffiliationE-mail
Zhang Shuang Ningxia Electric Power Research Institute 292747463@qq.com 
zengxueyang* Ningxia Electric Power Research Institute xueyangzeng@126.com 
Hits: 1764
Download times: 581
中文摘要:
      针对交直流并联运行系统阻尼不足、存在区域间低频振荡的问题,本文提出一种基于混合H2/H∞控制理论的交直流并联系统的机网阻尼协调控制策略。首先采用最小二乘-旋转不变算法辨识出系统振荡模式和开环降阶模型,结合混合H2/H∞控制理论,在高压直流输电和发电机中设计了附加鲁棒阻尼控制器,该控制器采用线性矩阵不等式的求解方法和输出反馈构造,求解容易,控制器构造简单,具有较强的鲁棒性。最后在PSCAD/EMTDC中搭建四机两区域测试系统,并与传统附加阻尼控制器对比,仿真结果验证了机网阻尼协调控制的有效性、鲁棒性。
英文摘要:
      In light of the low damping and low frequency oscillation problems of AC/DC parallel power system, a coordinated damping control method of generator and gird in AC/DC parallel power system based on mixed H2/H∞ control theory is proposed. Firstly, system oscillation model and open-loop reduced order model are identified by the total least squares-estimation of signal parameters via rotational invariance techniques(TLS-ESPRIT) algorithm. Combining H2/H∞ control theory and adopting the solution method of linear matrix inequalities and the output feedback structure, the supplementary robust damping controllers of high voltage direct current(HVDC) and generator is designed, whose advantages are easy to be solved, with simple construct of controller, and having strong robustness. In the end, a four machine in two domains test system is built in PSCAD/EMTDC, and compared with the traditional additional damping controller, the simulation results verify the effectiveness and robustness of the coordinated damping control of generator and gird.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd