一起合并单元故障引起的保护误动事故分析
A protection false action analysis caused by fault merging unit
Received:December 11, 2017  Revised:December 11, 2017
DOI:
中文关键词: 智能变电站  合并单元  主变保护  事故分析
英文关键词: intelligent substation  merging unit  transformer protection  accident analysis
基金项目:
Author NameAffiliationE-mail
ZHOU Wenyue* Sichuan Electric Power Research Institute 195157732@qq.com 
LI Xia Chengdu Power Supply Company 307288423@qq.com 
Hits: 1529
Download times: 824
中文摘要:
      分析了一起110kV变电站的主变低压侧合并单元故障引起的主变保护误动事故。通过加量试验、波形分析,并结合故障合并单元的硬件结构,确定了合并单元的故障是由FPGA芯片异常,导致采样数据的符号位被清0造成的。结合事故分析过程,介绍了故障合并单元的硬件结构,并对其设计缺陷进行了分析。
英文摘要:
      It analysed a transformer protection false action which was caused by fault transformer low voltage merging unit in a 110kV substation. By testing and analysis of wave and merging unit structure, it was confirmed that the false action was caused by abnormal FPGA which caused that the Symbol bit of Sampling data became zero.Combining the analysis of accident, the hardware structure of merging unit was introduced.And its design faults was analysed.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd