含光伏的主动配电网非对称故障条件下对并网点电压影响的研究
Research on active distribution network and network effects on non symmetrical voltage fault conditions with PV
Received:December 21, 2017  Revised:December 21, 2017
DOI:
中文关键词: 不对称故障  分布式电源  中性点电压击穿  并网点电压
英文关键词: asymmetric faults, distributed power supplies, neutral point voltage breakdown, point of common coupling
基金项目:江苏省普通高校研究生科研创新计划项目(SJZZ16_0291)
Author NameAffiliationE-mail
Qingrong Zhu NANJING INSTITUTE OF TECHNOLOGY 745599730@qq.com 
Han Li NANJING INSTITUTE OF TECHNOLOGY joneinxz@163.com 
Xianyun Li* NANJING INSTITUTE OF TECHNOLOGY alixy6412@aliyun.com 
Shuzheng Wang NANJING INSTITUTE OF TECHNOLOGY 191306248@qq.com 
Hits: 1425
Download times: 604
中文摘要:
      对于地区二次变电站其中性点一般不直接接地,随着高密度分布式电源的接入,若输电线路发生接地故障,会导致该变压器中性点电压升高,甚至会击穿,进一步影响并网点电压。本文针对含光伏的主动配电网,分析了主变中性点击穿前后、线路保护动作前后,影响并网点电压的主要因素,并画出含光伏的主动配电网的各序网络图,推导光伏电源并网点电压理论计算公式,同时,本文通过PSCAD仿真验证了公式的正确性,比较了主变中性点击穿前后,分布式电源并网点电压变化规律。
英文摘要:
      For a typical radiation type 220-110-10kV grid, the neutral point of the 110kV side transformer is a direct grounding system, but not the neutral point of each transformer is directly grounded. If the ground fault occurs on the 110kV transmission line, the neutral point voltage of the 110kV transformer will rise. Even the neutral point voltage breakdown will happen. This article will draw out the sequence network including photovoltaic power and calculate formula of distributed power and network voltage theory. Aiming at the typical power grid, respectively the main changes from the neutral breakdown occurred will be discussed at the same time. By analyzing the formula, the main factors affecting the voltage are obtained. The conclusion is of practical value. At the same time, the accuracy of the conclusion is verified by PSCAD simulation. The distributed power and the operation of point voltage are compared considering work condition of the main transformer.#$NLKeywords: asymmetric faults, distributed power supplies, neutral point voltage breakdown, point of common coupling
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd